Despite the development of alternative energy, humanity still actively uses conventional energy sources, in particular gas. The South Korean manufacturer has been producing heating boilers for decades and is rightfully one of the world leaders in this field. It makes sense to take a closer look at the products of this manufacturer.

About Kiturami products

The company was founded in 1962 and all these years has honed its skills in the production of heating boilers. During this time, the company's products have gained trust in the markets of Russia, Japan, Europe and the rest of the world.

The main activity of the manufacturer is the production of heating boilers, chimneys and other elements necessary for the installation of a heating system.

The following types of products can be distinguished:

  • boilers, and models are available that run on both gas and liquid or solid fuel. Solid fuel boilers Kiturami can work either for ordinary firewood, or on wood granules (pellets) and are characterized by high efficiency;

Note!
The boilers are produced as double-circuit boilers, so they can be used not only for heating, but also for hot water supply needs.

  • fuel tanks;
  • fuel pumps;
  • expansion tanks;
  • chimneys etc.

Overview of heating boilers

Considering the cheapness of gas for the population in our country, Kiturami gas heating boilers are especially popular. Such devices are distinguished by their compact size, high power, ease of maintenance and installation. There are several series of heating devices - 3 series marked World (Plus, 3000 and 5000), as well as Twin Alpha.

Features of World 3000 and 5000 series boilers

Particular attention to the issue of heating efficiency - common feature all Kiturami heating devices, not only gas ones (efficiency exceeds 90%).

As for the World series, we can highlight the following features of their work:

  • several operating modes - for ease of adjustment, the modes are designated as “Absence”, “Shower”, etc.;
  • advanced safety unit - gas analyzers will instantly “sense” a gas leak and turn off the device;
  • turbocharging guarantees stable draft, combustion products are instantly drawn into the chimney;
  • the power is sufficient to heat a large area;

  • You can adjust the temperature in literally 1 ᵒC steps hot water;
  • automation constantly monitors the condition of the main components of the heating circuit. For example, if there are power outages, the boiler will turn off, because circulation pump will stop working and coolant circulation will be at risk.
  • The self-diagnosis function looks interesting. In the event of a malfunction, a person can determine the malfunction by the illuminated number (of course, with the help technical documentation).

The only fly in the ointment can be considered the slightly unusual design of the boiler. In particular, in the World series, a person unaccustomed to Kiturami products may be confused by the location of the opening for air intake and exhaust of combustion products. When replacing a chimney with your own hands, this may become a small problem, but this drawback cannot be considered critical.

Triumph of Science – Twin Alpha Series

Devices in this series are considered the most modern and technologically advanced.

Among the features of Twin Alpha boilers it is worth noting:

  • extreme efficiency, when switching to standby mode they consume about 1 W of energy;
  • the heat exchanger is made not of steel, but of pure copper and aluminum; the thermal conductivity of these metals is higher than that of steel.

The series includes 5 models, differing in power and dimensions. So, heating boilers Kiturami Alpha 13R at its peak can produce a power of about 15.1 kW, which will be enough to heat a living area of ​​150 m2, while in hot water supply mode water can be supplied at a speed of 8.6 l/min. The weight of this model is 26 kg.

The most powerful model, Alpha 30R, produces up to 34.8 kW and is capable of heating a house with an area of ​​340 m2; in hot water supply mode, water is supplied at a speed of 20 l/min.

Note!
Despite the much greater power, the size and weight of the boilers do not differ much.
Thus, the mentioned boiler models differ only in width (the more powerful one is 5 cm wider) and weight (the Alpha 30R model weighs 3 kg more).
So there will be no problems with installation.

As for the cost, the Twin Alpha series is on average 10 - 12 thousand rubles cheaper than World3000.

For example, the Alpha 20R model costs about 30 thousand rubles, and the price of a comparable device in the World3000 series is about 42 thousand rubles.

Installation Features

  • the weight of the wall-mounted model is 30 – 45 kg, so it is not recommended to place it on light partitions, the best option can be considered a load-bearing wall for installation;
  • It is recommended to use a rubber gasket to reduce noise from possible vibration;
  • It is advisable that the installation site is not over-moistened.

Particular attention should be paid to the installation of the chimney; it is used to remove combustion products. coaxial chimney. To facilitate work, the use of telescopic chimneys is allowed.

Instructions for installing the pipe look like this:

  • when connecting individual elements sealing tape must be used, and the tightness of the joint is achieved by tightening the connecting bolts;
  • in case of pipe outlet beyond the wall, the manufacturer recommends limiting maximum length within 2.5 m;

Note!
The pipe is given a slope of 3-5ᵒ in order to ensure condensate drainage.

  • As for the installation of a pipe through the roof, it is necessary that a free descent to the pipe be provided along the entire length of the pipe;
  • the horizontal section of the pipe in the section from the boiler exit to the vertical section should not exceed 90 cm, otherwise the draft may deteriorate.

Summarizing

Heating boilers are popular not only in country houses, but also within the city limits, because heating system provides a lot of advantages compared to centralized ones. Kiturami boilers can be considered one of the most high-tech offerings on the market; high efficiency, durability, and the ability to flexibly regulate operation only contribute to the growing popularity of this manufacturer’s products.

The video shows in detail the principle of operation gas boiler Kiturami.

Every day, heating equipment made in Korea is gaining more and more attention on the Russian market, offering high quality, reliable operation and reasonable cost. A review of boilers from the Kiturami company, reviews from owners and descriptions of technical characteristics will help you better understand the types and features of products, as well as make right choice at the time of buying.

The range of heating boilers from the Korean manufacturer Kiturami is grouped according to several characteristics:

  • type of installation – wall or floor;
  • type of energy source used - liquid, solid fuel, gas or combined;
  • possibility of hot water supply - single or double circuit;
  • combustion chamber - open or closed.

Description of gas, diesel, solid fuel and combined boilers Kiturami:

1. Liquid fuel Korean heating systems Kiturami boilers Turbo have a set of characteristics that can fully satisfy user needs:

  • The turbocyclone burner creates an aerodynamic flow, increasing efficiency.
  • Turbocharging promotes secondary combustion of combustion products in a specially installed cylindrical chamber and their forced removal.
  • The security system includes combustion sensors, temperature and overheat control, as well as lack of coolant and fuel.
  • This series uses new model chimney Kiturami, whose efficiency is 2-3% higher than that of a similar class of boilers.

Turbo is a representative of the most economical boilers available on the market - the average consumption is 8 l/day.

2. Wall-mounted double-circuit gas boilers Kiturami heating systems (World 3000, World 5000, World Plus and Twin Alpha) are distinguished by their affordable cost and reliability. Built-in circulation pump and expansion tank facilitate installation, and set installed sensors performs security controls gas equipment.


Buying a World Plus-13R gas boiler will cost 32 thousand rubles, and the cost of a Twin Alpha of the same power will be about 24,000. Structurally, the Kiturami TGB representative can be called an analogue of the Turbo, but designed to operate on liquefied gas. Repeated passage of combustion products in a steel three-pass heat exchanger reduces noise levels and increases efficiency. The turbocyclone burner of the stationary heat generator of the KSOG series ensures stable operation of the boiler during pressure drops in the gas main, and also promotes secondary combustion of gases. The electronic control unit and thermostat-regulator maintain the desired indoor microclimate.

3. Biofuel heating boilers from Kiturami for home KRP series have the following features:

  • The feed auger automatically doses wood fuel.
  • The integrated design of the heat exchanger in the smoke and water pipes allows for an increase in efficiency of up to 92%.
  • A circulation pump is built into the water tank of the heat generator for maximum heat transfer.
  • Multi-stage gas outlet avoids backfire.
  • The automatic grate cleaning system mechanically removes “cakes” of baked pellets, which prevents overconsumption.
  • The pellets are ignited by a ceramic heating element from the Japanese company FKK.

The cost of the Kiturami KRP-20 biofuel boiler is about 140,000 rubles.

4. STS presents stationary combi boilers with compact dimensions for installation even in small spaces. Design features make this series economical and guarantee long-term use (10 years):

  • A Kiturami turbocyclone burner and a special swirl screen promote complete combustion of fuel and reduce carbon monoxide emissions into the environment.
  • An improved grade is used to manufacture the heat exchanger of stainless steel with patented welding technology.
  • Advanced auto diagnostic system.

The Kiturami model line includes cast iron boilers(KF series), intended for heating small rooms, the disadvantage of which is the need to periodically monitor the firebox and add firewood. But the price of KF solid fuel boilers is two times lower than their pellet “brothers” - about 70,000 rubles.


Features of Kiturami products

Kiturami modelDescriptionPrice, rub
Turbo-13R
  • diesel double-circuit boiler 15.1 kW;
  • Efficiency – 93.2%;
  • DHW – 8.4 l/min;
  • consumption – 1.5 l/hour.
27 200
Turbo-30R
  • liquid fuel heat generator with the ability to replace the burner with another type of fuel (gas);
  • power – 34.9 kW;
  • DHW flow – 20.7 l/min;
  • diesel consumption – 4.3 l/hour.
38 690
KSOG-50R
  • stationary double-circuit heat generator with a power of 58.1 kW, sufficient to heat 580 m2 of area;
  • copper DHW circuit;
  • Provides maximum DHW flow of 33.3 l/min;
  • Efficiency – up to 92.9%.
96 840
World Plus-13R
  • gas wall-mounted boiler Kiturami 15.1 kW, designed for closed system heating;
  • two heat exchangers – copper and steel with storage;
  • Efficiency – 94.2%;
  • DHW – 8.7 l/min;
  • allows the use of antifreeze.
32 100
Twin Alpha-25R
  • wall-mounted gas boiler Kiturami with a power of up to 29 kW;
  • copper-aluminum heat exchanger;
  • Efficiency – 91.6-91.8% depending on the load;
  • lightweight expansion tank – 7 l;
  • DHW flow – 16.7 l/min.
27 800
STSO-13R
  • stationary diesel thermogenerator with the possibility of conversion to gas type fuel;
  • power – 16.9 kW;
  • dual circuit with closed camera combustion;
  • Efficiency – 90%;
  • Kiturami service life is more than 10 years.
27 520
KRP-20A
  • free-standing solid fuel boiler with forced ventilation;
  • thermal power – 24 kW;
  • Efficiency – 92.6%;
  • average consumption granules (up to 32 mm long) – 5.53 kg/hour;
  • Fuel capacity in the bunker is up to 160 kg.
139 900
KRP-50A
  • double-circuit pellet boiler Kiturami with modulating burner;
  • power – 50 kW;
  • heat exchanger made of stainless steel;
  • Hopper capacity – 300 kg.
169 900

What do you need to know when choosing?

The wide range of products offered by the Korean manufacturer is extensive, making it difficult for the average consumer to purchase. Therefore, the selection of heating equipment should be carried out according to the main characteristics of Kiturami:

  • Type of fuel used and efficiency. The choice of energy source for operating the units depends on the capabilities and desires of consumers.
  • Thermal power. A double-circuit thermogenerator must fully provide both space heating and water heating for household needs.
  • Installation type. Wall boilers They are compact in size, but floor options greater power range.
  • Heating system. The selection of a specific model depends on the planned type of heating circuit - open or closed, as well as on the coolant circulation - in a natural way or forced.
  • The heat exchanger material affects the life of the boiler, its efficiency and cost.

Even at the stage of designing heating in a house, you have to operate with the general technical characteristics of the boiler, but in the end you still need to go to the store and choose a very specific model from the huge assortment on the market.

It will be useful to find out in more detail what a Kiturami diesel boiler is, what models are in the line, and how they can be better than other offers on the market.

Features of Kiturami boilers

Kiturami is a South Korean company with more than half a century of experience in the development and production of heating boilers and related equipment.

During this time, the company became one of the leaders in the domestic Korean market, and also found an extensive market in North America and nearby Asian countries. In our country, Kiturami boilers have been officially distributed for at least ten years and have already managed to show their good side.

The main emphasis in promoting boilers is on the implementation innovative technologies and in particular, our own developments, which have no analogues from other manufacturers or determine the narrow specificity of the equipment’s operation.

Diesel boilers, by definition, are not considered as the main the lineup for a wide range of applications. In respect of economic feasibility they are inferior to gas, electric and even solid-state boilers. However, they are still in demand among consumers due to a number of reasons why liquid fuel is becoming preferable.


In remote areas of residence, where there is no stable connection to power grids and no gas supply, the issue of fuel availability becomes acute. At the same time, the heating of the house must, by definition, work uninterruptedly throughout the entire season. If for many countries such situations are rather the exception to the rule, then for us, on the contrary, they are commonplace, the reason for which is the vast expanses that separate populated areas.

Diesel fuel, unlike gas, is easier to transport and easier to store. minimal risks for life and environment. Unlike solid fuel boilers, diesel fuel, when burned, provides uniform heating and a greater degree of control over resource consumption. And finally, the design of a diesel boiler and, in particular, the burner does not limit the use of other heat sources.

With minimal changes diesel burner can be replaced for the use of blue fuel, and boilers equipped with an extensive combustion chamber and grate, can quickly switch to using coal, wood or pellets.

Kiturami diesel boilers are highly technologically advanced and are ideally balanced equipment for using diesel fuel as a heat source, and at the same time they are excellent for the listed types of conversion to operate on gas or solid fuel. So constructive and functional flexibility is the first significant advantage.

Kiturami boilers often use their own developments and a unique layout. On the one hand, this reduces the maintainability of heating equipment, but on the other hand, it ensures the highest boiler efficiency and balanced operation while observing simple and transparent operating rules. This is the second significant reason to pay attention to diesel boilers originally from South Korea.

The last advantage is the cost of boiler equipment. Even taking into account the high performance and proven quality of the boilers, their cost does not exceed the market average among similar offers.

So it turns out that Kiturami boilers have three features: a balanced design, high efficiency And affordable price.


Kiturami boiler design

Specifications

The operational characteristics, dimensions and parameters of Turbo series boilers are presented in the table below. It is clearly seen that the series of floor-standing diesel boilers covers a power range from 10 to 35 kW, which is quite enough to heat houses up to 250-275 square meters. Part of the heat will be used to prepare hot water, which must be taken into account in the calculations.

All Kuturami double-circuit boilers and heat exchangers, by the way, are ideally designed specifically for these tasks.

Boiler modelUnit changeTURBO-9RTURBO-13RTURBO-17RTURBO-21RTURBO-30R
Powerkcal/hour9000 13000 17000 21000 30000
PowerkW10,5 15,1 19,8 24,4 34,9
Fuel consumptionliter/hour1.13÷1.51.6÷1.971.87÷2.152.28÷2.803.75÷4.30
Efficiency% 92 92 92.2 92.4 91.8
DHW consumptionΔt=25ºC6,0 9,7 11,3 14,0 23,3
Δt=40ºC3,8 6,1 7,1 8,7 14,6
Heating supply and returnmm25 25 25 25 25
Hot water inlet/outletmm15 15 15 15 15
Chimney diametermm80
Power supplyV/Hz220/50(60)
Energy consumptionW80 160
External sizew×d×h325×600×835365×650×930
Weightkg60 79 85 85 85

Fuel consumption

Fuel consumption is shown in the table with technical requirements. However, please remember that actual consumption depends on individual settings. Based on the actual power required to heat the house, an appropriate nozzle is selected from the set offered by the manufacturer.

Thermal power, fuel consumption and fuel combustion mode are set. The parameter indicated in the table displays factory presets sufficient to ensure proper performance provided that only high-quality fuel is used, more often this means diesel fuel with winter additives that do not allow it to thicken or separate paraffin in excess of the norm.

In a real situation, for a boiler model with a power of up to 15 kW, you can expect fuel consumption at 8 liters per day taking into account the frequency of burner operation and optimal temperature regime in the house. However, this is not the limit.

The right approach to choosing a heating mode, as well as installing a controller with variable temperature conditions, for example, depending on the time of day and day of the week, can reduce consumption even more.

Chimney

Cuturami boilers, gas, diesel, floor-mounted or wall-mounted, are mostly equipped with a closed combustion chamber and, accordingly, compulsory system exhaust gas removal. The Turbo series, which we are in, is no exception. this moment We are considering.


Chimney installation diagram

The chimney for boilers is coaxial for simultaneous supply fresh air from the street and exhaust gas removal. Since the exhaust temperature after passing through the heat exchangers is no longer high, the requirements for the heat resistance of the chimney are reduced, and the list of acceptable materials is expanded.

In the best case, a steel coaxial chimney is still used, but a ceramic vertical chimney with a group of internal separate channels for supplying air, removing gases from the combustion chamber and ventilating the boiler room can be effectively used in the same capacity.

The size of the chimney is strictly indicated in the boiler specification and operating instructions. For the entire Turbo series it is 80 mm.

You can make a small chimney if you wish larger diameter, but not more than 50% above the specified value, that is, up to 120 mm.

Under no circumstances should the size and cross-section be reduced. Even though the removal of combustion products is forced, the resistance of the chimney will greatly affect the combustion mode and the quality of fuel combustion.

turbo 13r

The boiler model number corresponds to the amount of heat generated per hour - 13,000 kcal/hour. Converted to conventional kilowatts, the resulting value is 15.1 kW.

The declared power is enough to heat a house with an area of ​​up to 150 m2. Naturally, one should take into account the heat costs for preparing hot water. If a significant consumption of hot water is predicted, and regularly, then the thermal power for the heating circuit will naturally be lower.

Reliability and balanced operation, combined with the affordable cost of the boiler, gives a clear advantage in the case of using several boilers simultaneously in one building, for example, when dividing the heating circuit for each floor separately or when covering a large area in two more directions.

turbo 17


Boiler Kiturami turbo

Thermal power already reaches 19.8 kW, which is enough to cover the heating of a house with an area of ​​up to 180 m2. It is possible to reasonably increase the upper performance threshold by selecting the appropriate nozzle on the burner, however, this will affect fuel consumption.

This approach allows you to solve the problem with increased DHW consumption so that without extra costs do not hesitate to use hot water even in the most severe frosts.

turbo 21r

With a further increase in power comes a model with a declared performance of 24.4 kW, and at the same time the performance of the DHW circuit increases significantly. It should be noted that the dimensions of the boiler do not change compared to younger models.

turbo 30 r

The most powerful model in the Kiturami line of liquid fuel boilers. A performance of 34.9 kW makes it possible to heat a room up to 350 m2, but at the same time The cost of the boiler at retail is approximately 45-46 thousand rubles., which is undoubtedly an attractive option.

As in the entire line of boilers, burners with a unique torch shape and optimal fuel combustion mode are used.

A minimum amount of nitrogen oxides is recorded in the exhaust, which indicates the high environmental friendliness of the equipment.

Settings

It is better to entrust the initial startup and setup of Kiturami boilers to a specialist who can correctly determine the optimal operating mode, select the desired type of nozzle and check the fuel consumption depending on its characteristics and even the method of connection and location of the fuel tank.

Nozzle for diesel boiler

For self-installation, the boiler is supplied with detailed instructions, according to which it is possible to determine the operating mode closest to the design value.

The main thing is to adhere to the sequence of actions defined in the technical documentation and visual aids for putting the equipment into operation.

Setting up and adjusting the boiler settings should be carried out not only at the first start-up, but also during preventive maintenance before each new season and to switch to summer mode, in which only the DHW circuit will be used.

Malfunctions

Kuturami boiler equipment is supplied a full-fledged system self-diagnosis based on the operation of a number of sensors. The controller is able to assess the condition of the equipment, as well as the current operating mode, and respond to any deviations or problems that arise during operation.

In any emergency situation, the main action assigned to the boiler controller is to stop the burner to prevent significant consequences.

A well-developed self-diagnosis algorithm allows you to identify the problem and indicate the error code on the display so that the user can quickly take all necessary actions to repair and restore functionality.

Among frequent breakdowns Kiturami diesel boilers:

  • No ignition (error code 01);
  • Does not start, there are no messages on the display.;
  • Coolant leakage (depressurization of the heat exchanger or one of the pipeline connections);
  • The flame goes out periodically emergency stop boiler;
  • There is no draft, the operation of the boiler is accompanied by the flow of smoke and exhaust into the room.

Error 01 and solution

If error code 01 appears on the boiler display screen, it means that for some reason the fuel did not ignite, there is no torch, the controller forcibly stops the fuel supply, displays an error message, and signals the problem to the user.

Solving the problem requires precise execution of a procedure that can identify the source of the problem and eliminate the obstacle in the operation of the boiler as effectively as possible.

IN in brief the procedure looks like this:


Quite often, the fuel-air mixture is supplied under too much pressure into the chamber and therefore does not have time to ignite from the electrode. The problem is solved at the 5th step of the algorithm by adjusting the air damper, which causes a mixture with a changed concentration to enter the chamber.

Doesn't start

The most unpleasant situation is when the boiler simply does not turn on. There are no signals on the display, and accordingly there is no error code by which the malfunction can be determined.

In such a situation, it would be appropriate to call a specialist service center, who will be able to understand the situation and give the correct verdict, as well as determine the repair procedure. You can independently only check the presence of voltage in the network, as well as the fuses in the boiler.

Leak

Most often, a leak means that the seal has been damaged in some connection of the pipeline inside the boiler. It is enough to inspect the equipment and determine the location of the leak and replace the gasket.

The heat exchanger in Kiturami boilers is made of alloy steel and copper, so it does not leak without obvious errors in the selection of coolant or mechanical damage.

Burner goes out periodically

Most common cause is a malfunction in the burner settings. It is important to adjust its power and use a gas analyzer to determine optimal ratio air/fuel for complete combustion. You cannot do such work yourself, so it is better to contact a service center.

There is no draft, smoke and exhaust enters the room

Most likely, the burner fan is not working for some reason. It is important to first check that the impeller is intact and rotates normally.

It is possible that debris has accumulated inside the fan, or the impeller shaft is jammed. Next it is checked electrical part and control unit.

The work of the Kiturami concern is aimed at the production of heating devices using biofuel and gas. But it was the diesel fuel equipment that ensured the popularity of this manufacturer.

Advantages of diesel fuel installations:

  • Ease of use thanks to the ability to control any function using the remote control. The thermostat built into it determines the operating and temperature conditions. The operation of the boiler does not depend on the size and presence of draft, since the existing turbocharging effect contributes to the forced direction of exhaust gases into the chimney;
  • High efficiency is achieved due to aerodynamic flow during fuel combustion;
  • Possibility of self-configuration;
  • Year-round hot water supply;
  • Availability of a self-diagnosis system with information about the operation and malfunctions of the system;
  • Acceptable price;
  • Variety of model range.

The only negative is the type of fuel, which creates a negative environmental situation when burned.


Equipment characteristics

  • The design, equipped with high-quality elements and blocks, differs from other brands. The heat exchanger is made of highly alloyed steel, which has superior physical and technical properties to other metals, which increases its cost, which is compensated by its high quality.
  • The equipment is made of copper, which does not react with water and increases its heat resistance. The presence of internal and external control units, which helps regulate and control the operating mode of the system from different places in the boiler room.
  • Coverage of the power range of floor standing 2-circuit devices – from 10 to 35 kW, sufficient to heat 250-275 sq. m.
  • Dependence of actual fuel consumption on personal settings. An injector from the manufacturer is selected for the actual power parameters.
  • Heating power, fuel consumption and combustion mode are set independently. With power parameters up to 15 kW, the expected fuel consumption is 8 liters per day, while the burner will operate at certain intervals to create optimal room temperature. By correctly choosing the heating mode and installing a variable temperature controller, you can significantly reduce fuel consumption.
  • Gas, diesel, floor-mounted or wall-mounted boilers are mainly equipped with a closed combustion chamber and a forced gas exhaust system. The steel or ceramic chimney is coaxial, so that the supply of street air flow and gas removal are carried out at the same time.
  • It is possible to construct a chimney with a slightly larger diameter - up to 120 mm. Reducing its size and cross-section is unacceptable.

The lineup

The development of KSO models was initially carried out as gas-powered equipment. After changing the type of burner and slightly changing the monitoring and control system, it became possible to use other energy sources. Diesel fuel became the main fuel. The turbocyclone burner contributed to 100% fuel combustion and increased efficiency. The advantages of the model are simplicity of design, ease of maintenance and low price.


Biofuel boilers models KRM-30R and KRM-70R with changes made to their design, they use both diesel fuel and other solid fuel. The transition from one type of fuel to another is carried out quickly. System forced circulation helps to increase the efficiency of the heater. These models differ only in power.

Model turbo 13r generates 13,000 kcal/hour of thermal energy or 15.1 kW, which is enough to heat 150 square meters. m. Taken into account heat costs for the preparation of hot water supply. With significant regular waste of boiling water, the thermal circuit power is lower.


Model turbo 17 has a thermal power parameter of 19.8 kW, sufficient to heat 180 sq. m. To increase the upper performance threshold, nozzles on the burner are selected, which can affect fuel consumption.


Model turbo 21r with a capacity of 24.4 kW it has increased performance of the DHW circuit. At the same time, the dimensions of the boiler remain unchanged.

Liquid fuel model turbo 30 r has a capacity of 34.9 kW, sufficient for heating 350 sq. m. Equipped with torch-shaped burners, the fuel combustion mode is optimal. Due to the low amount of nitrogen oxides, it is a highly environmentally friendly equipment.


Price

  • Turbo models 15-35 kW for heating 150-350 sq. m, weighing 52-85 kg - cost 28 thousand-37 thousand rubles;
  • STS models 17-35 kW for heating 160-350 sq. m, weighing 40-58 kg - cost 29 thousand-43 thousand rubles;
  • KSO models 58-465 kW for heating 580-4650 sq. m, weighing 93-750 kg - cost 75 thousand-428 thousand rubles.

Owner reviews

“In 2012, a Kiturami 17R boiler was purchased. Great purchase. He was supposed to work as a backup for the Evan Epo-18 electric boiler, acting as the main one in heating system. Since an area of ​​150 square meters was heated. m, then the choice specifically fell on equipment with increased power. IN very coldy the main boiler cannot cope with maintaining the required temperature conditions and stops working due to a drop in voltage in the network. Kiturami acts as a lifeguard, heating and providing water.” Tambov, Arkady

“The Kiturami Turbo boiler is of interest for hot water due to the presence of the SHOWER function, which is capable of producing a small volume of hot water in a short period of time.” Sochi, Marina

“Wonderful equipment. No matter how many such systems have been installed, practically no one has any complaints. All of Siberia is heated by them.” Ekaterinburg, Sergey

“The cost of this equipment alone can attract interest. Spare parts are always available, the remote controls are unified.” Moscow, Konstantin

“We have our own complaints about the boilers of this company. In my opinion they are not entirely reliable. So we had to resort to repairs twice. Automation can’t handle it.” St. Petersburg, Alexander

Installation and operation rules


If there are voltage surges, it is advisable to purchase a stabilizer to ensure proper operation control and monitoring unit and safety from premature failure

The boilers are equipped with tanks for storing liquid fuel. These tanks may affect the performance of the equipment. Required correct installation this container, which must be aligned in all planes.

The tank must have a pipe for draining sediment and a fixing bag. The container must be periodically emptied of fuel and cleaned; it is recommended to use only purified fuel.

Before starting the equipment, the tank is initially filled with diesel fuel, which must sit for at least half an hour. Only after this the unit is started and operating modes are adjusted.

In the presence of power surges, it is advisable to purchase a stabilizer to ensure proper operation of the control and monitoring unit and safety from premature failure.

To maintain the operation of the boiler you need:

  • Periodic mechanical cleaning.
  • Constant monitoring of equipment performance and checking components and parts for leakage.

Possible self installation diesel boilers by carefully studying the manufacturer's diagrams and recommendations. However, there are many operations that require the presence of highly qualified specialists so that the equipment does not have to be repaired later. Instructions for the exact order and principle of installation and electrical diagram installation are used for clarity of these works.

Kiturami boilers are economical option with a long service life. The reason for premature repairs is untimely service maintenance or filling with low-quality fuel.

Error codes:

Reasons for lack of ignition - error code “01”:

  • The screw that limits the fuel level is jammed. It is necessary to replace the shut-off element or check the injection motor;
  • Charge motor failure– you will need to check the performance of the motor;
  • Lack of fuel supply– you will need to check its level;
  • Third Party Item in a screw gate;
  • Photosensor failure– it needs to be tested for functionality.

  • Diesel single-circuit and double-circuit models have been developed, the latter are more convenient, but more expensive. If you choose the first option, you will need to purchase a boiler and other appliances and accessories, but its cost will still be lower.
  • It is worth paying attention to the depth of the fuel intake according to the criterion for determining the deep location of the fuel and fuel tank. According to fire safety, fuel tanks must be buried in the ground to an appropriate depth. At low power, the intake depth is higher.
  • Equipment installation cost price will be included heater, its installation, commissioning and commissioning work, maintenance and spare parts for its repair.