Heating systems for country and country houses. Boilers, geysers, water heaters - Repair, service, operation. Recommendations for installation and installation. Gas wall-mounted boiler Master Gas Seoul. Characteristics of technical parameters Seoul 2 gas boiler

Specifications

Boiler type gas, convection Gas stove Number of circuits double-circuit Max. thermal power 21 kW Combustion chamber closed Heated area 210 sq.m Electronic control Wall installation Mains voltage single-phase Built-in circulation pump There is Built-in expansion tank yes, 4 l Fuel natural gas, liquefied gas Consumption natural gas 2.11 cu. m/hour Liquefied gas consumption 0.62 kg/hour Coolant temperature 40 - 80 °C Temperature in the DHW circuit
37 - 60 °C Hot water output at 25°C 11.5 l/min Max. water pressure in the DHW circuit 10 bar Max. water pressure in the heating circuit 3 bar

Comfort

Functions power indicator, thermometer, pressure gauge, auto-ignition, flame modulation, room thermostat, programmer
Peculiarities display, remote control

Safety

Protection autodiagnostics, gas control, overheating protection, frost prevention mode, safety valve, air vent Filtration water filter, gas filter

Connection

Gas connection pipe 1/2" Heating circuit connection pipe 3/4" DHW circuit connection pipe 1/2" Diameter coaxial chimney 60/100 mm Connection of a separate chimney (diameter 80 mm) yes Dimensions (WxHxD) 400x645x200 mm Weight 24.5 kg price and quantity indicated as of February 17, 2020, 9:00

wholesale price on request(call)

Wall-mounted double-circuit gas boiler with closed camera combustion MASTER GAS SEOUL is designed for heating and hot water supply of residential buildings with an area of ​​up to 210 m2.

Production - Korea

In general, the boiler leaves a pleasant impression of the quality of workmanship and assembly. At low cost boiler, the quality is very acceptable. All components in the boiler are located at a distance from each other, which is important when servicing the boiler. The pump is a little noisy.

Advantages and features of Master Gas Seoul boilers:

  • Modern ergonomic design
  • Automatic maintenance of the set temperature with an accuracy of 1°C in heating and hot water modes
  • Two separate heat exchanger for heating and domestic hot water circuits
  • Copper primary heat exchanger
  • Forced removal of combustion products
  • Multi-level security system
  • Self-diagnosis system
  • Availability of a control panel.

The combustion chamber

closed

natural / liquefied

Minimum heating capacity, kW

Working water pressure in the DHW line, MPa

0.015? 1.0Minimum water flow for switching on, l/min 2.5

Gas pressure in the pipeline (natural/liquefied), kPa

Nominal gas flow (max./min.), m3/h

Nominal capacity in the DHW circuit, kW

Efficiency at rated power,%

Heated area, m2

Temperature range in the heating circuit, o C

Temperature range in the DHW circuit, o C

Chimney diameter, mm

Diameter of separate smoke exhaust pipes, mm

Type of combustion products removal

Forced

Coolant

Maximum consumption electrical energy, W

Guarantee

24 months + 6 months

Manufacturer country

The Master Gas Seoul gas boiler is in operation, and questions have arisen. I attached two thermometers next to the remote control and the readings on them coincided, but on the remote control. When the apartment is 22 degrees. on the remote control it is 24 degrees, and when the apartment is 24 degrees on the remote control it is already 27. How can this be fixed? Maybe someone knows how to get into the remote control menu with greater rights? Once in the menu, as described in the instructions, it is impossible to change the boiler power, however, like many other settings.

Settings in the remote control become available when you turn on switch block No. 3.

Malfunction gas boiler Master Gas Seoul 16. We have been using it for 2 months. There are already problems with ignition. The claps are sometimes so strong that it becomes scary.

Obviously the gas workers connected the gas, but did not adjust the pressure.

In general, there are a lot of problems with heating: a hum, periodically appearing white smoke (steam?) from the chimney, and, what is most unpleasant, a regular drop in pressure in the system. Water has to be added every ten days. There are no visible leaks, the built-in expansion tank can be blamed on the insufficiency (due to lack of funds, I hung up the existing steel panel radiators Soviet-made, so it is quite possible that the coolant volume is more than the recommended 50 liters), however, jumps into the red zone and discharges of extra pascals after this are not observed. I don’t want to admit it, but perhaps the only correct assumption, in my opinion, is a malfunction of the boiler heat exchanger (crack) due to which water constantly seeps into the combustion chamber, as a result of which the pressure in the system drops and white smoke comes out of the chimney. I will be very grateful to everyone who expresses their opinion.

One of the reasons is that the coaxial chimney is not installed correctly (no slope) and condensate enters the combustion chamber and, again, incorrect gas regulation.

A 140 kW Master Gas Seoul wall-mounted boiler is connected in a one-room apartment. The developer filled the heating system with plain water. I had no previous experience with this technology, so several questions arose. I want to fill the system with distilled water. After reading, I basically understood how to do this: using a pump, we pump cold water through the inlet fitting that fits into the device, open the make-up valve and wait until the coolant is pumped into the system and, accordingly, the required pressure appears. Then we shut off the whole thing simultaneously, bleed the air and start the boiler. Please correct me if I'm wrong. During operation, the water will still evaporate a little and the pressure will drop. To raise it, I just need to open the feed tap and then water from the main will replenish the system to required pressure? According to those passport, unit
requires connection electrical part through a power stabilizer. I would like to hear opinions on this matter, whether this condition is critical. I understand that there is a microcircuit inside that is afraid of voltage surges, but still? I want to install a filter on the cold water line in front of the boiler. Please advise, at least which one to choose, maybe special filters are used here?

There are 20 liters of water in your heating system. And this will not cause problems if you do not add the same amount or more every day. Better check for leaks.

When the Seoul 14 gas boiler operates using an air temperature sensor, it turns out somehow crooked. The sensor is lying, and the error is not linear. The temperature in the room ranges from 22 to 24, and on the remote control it is 26 (the thermometer is next to the remote control, and away from the battery). During the pause, the batteries cool down completely, and from constant heating and cooling changes, smudges may appear on the winding. You have to adjust the system water temperature when working using the air sensor, and with this remote control, unlike the Navien, this is not convenient. In general, the temperature in the apartment is more stable, and the batteries are always hot when the boiler is operating according to the water temperature in CO, as long as there are no strong temperature changes outside. Ideally, it would be if the water temperature of the system was adjusted automatically based on the air temperature in the apartment! Here's how to do it?

Although theoretically, if you take a PID controller for an MEO with a resistance thermometer, connect it to the remote control buttons, a boiler based on the temperature in CO, it might work out. With a large integration coefficient, the controller will be more inert, waiting for a change in the signal from the sensor. You just need to think about a circuit that will duplicate the output of the regulator to the remote control button; you need to press the remote control button twice.

Tell me, what kind of heating system tap is this and where can I turn it off? Because the water from the DHW circuit does not correspond to that set on the remote control (much colder, not even 60 degrees hot). Or has anyone encountered this?

The taps on the heating system are mounted in front of the boiler - on the supply and return. The water flow is too big. Gas pressure is low.

Set it to 11 kW. The pump makes noise and gets hot. The pump temperature is 2 times higher than that of the carrier. But the hand endures. This is fine? Pump A3 error occurred several times. Where to bleed air out of it? I can't find the plug. Or do I need to open the air vent? And How? Maybe it's running dry?

There is no plug, but the air vent can be opened.

A wall-mounted boiler is in operation Master gas Seoul 16. Tell me what to do: the pressure is on the verge of the minimum permissible (about 1 bar) when opening the make-up tap it does not increase or sometimes increases slightly (1.1 bar). What could be the reason? And it still buzzes very loudly. The pressure in the water supply is like 4.5 atmo, if that.

As for the first, maybe the make-up system is clogged, we need to look at what exactly, how the expansion tank behaves, and what exactly does the pressure gauge show? As for the second, if it hums, you need to find out that the pump is humming or the heat exchanger is clogged. Go to the remote control settings value P8 from 31 put 20 in the passport according to the table there is a typo. The buzzing will pass.

The Master Gas Seoul 16 boiler is malfunctioning, error AA constantly pops up, sometimes A4. It turns out that it starts to boil, and when it boils, the pressure gauge for heating goes off scale. The water pressure through the boiler is 2 times worse than cold water. What could it be?

If it boils, it means there is poor water flow, check the system or the Primary heat exchanger is clogged. And the fact that the pressure increases, then it will be so, since when it boils it increases, and look at the DHW heat exchanger.

A gas boiler is in operation, Boiler Seoul 14. Tell me what to do. According to the passport data for the boiler, the minimum water flow in the system to turn on the boiler in DHW mode is 2.5 l/min, and for me it turns on when the water flow is 6-7 l/min (I took measurements practically), in addition this also increases water consumption . The service people say that nothing can be done. Is not it?

Maybe the DHW flow sensor is jammed, if it is possible to disassemble it and check it, I think there shouldn’t be anything complicated there, or it could be defective.

I called a serviceman from Gorgaz. The problem was solved by adjusting the maximum pressure. However, with the recommended value of 55, I had to set it to 40, otherwise the hum would not go away. Again, it is not clear how this will affect the set and maintenance of the set temperature in winter. And it turns out that these models regularly, about once a year, damage the switching valve from heating to DHW.

The primary heat exchanger is clogged. Flushing is needed.

Gas boiler MG Seoul 14 installed and connected closed system I didn’t see the heating, how they poured antifreeze. In general, after the time has elapsed while gas was being filled, the pressure has dropped and the boiler does not start, how can I increase the pressure?

Look, there must be a faucet, but in general you need to find out from the people who were involved in this, or at least be present at the first start-up, so that such questions would not arise later, but look - this must be the case, you will need a pump.

Malfunction of the gas boiler Master gas Seoul 21 with a water heater. In December it will be two years since it started working. It's broken 3 times already. Error A4. The heat exchanger was replaced for the first time. They said that it was clogged because someone opened some kind of tap there. And he installed it himself. In the spring, when the boiler gave the same error, another technician arrived, turned it on, adjusted the pressure, and the device started working on its own. Now this error is happening again. We also washed the previous heat exchanger in case of replacement. We have water filters at the entrance. Tell me, is this the norm, that in 1.5 years of service we have already repaired it 3 times?

The wall-mounted boiler is humming. Master gas, how to switch the control board to service mode, otherwise it doesn’t work from the remote control.

There are three microtoggle switches on the top of the board, move the top two to the opposite side and go to settings, then return it to its place.

Tell me what could be happening: on the third day, water is dripping heavily from the tube below and the pressure drops? Yes, and air appears in the first battery. Maybe the air vent is clogged? Can it be fixed or just replacement? Seoul-14 boiler, three months. Works intensively for a week (frost), works according to air temperature.

Hit the air vent with a screwdriver, it will close and there will be no dripping.

Tell me, the value for “setting the fan speed” (forced minimum combustion) in the L2 passport is 40. Today I compared all the parameters with the passport, L2 is set to 36. Should I leave it or set it as in the passport?

If the minimum gas pressure on the boiler burner decreases below that set by the manufacturer, gas consumption will increase!

Malfunction of the Master Gas Seoul 21 boiler. Installed in the spring, it worked fine, in the winter it began to hum strongly, and if you press the lid with your hand, the hum disappears a little. It turned off several times with error A6. However, when turned on again it worked fine. But there is a hum, I don’t even know what to do. By the way, could the hum be due to the fact that the heating pipes are PP 20? Also, tell me: what are the P8 settings for 16 kW?

In the passport - 20, in fact - 31.

The boiler filter (under the pressure gauge) has already broken off several times. Everything seems to be in order, the pressure in the CO is normal, and it doesn’t show any errors either. It heats normally, according to the settings, and the hot water is also fine. It was knocked out, screwed the filter back in, added water - everything was in order again. Last year, a friend had the same problems - he kept tearing it up until the control board flooded - they replaced it and everything got better. The device is already 3 years old - there have been no problems - only air was sometimes pumped into the expander. Tell me, please, what to do?

Does anyone know how to increase the boiler power? When I bought the boiler, the seller said that it was possible to make a boiler from the 16th to the 21st using a switch on the board. Is this possible? Do all models have the same board with controller? Maybe you can reflash the controller? Has anyone messed with the controller?

Can you tell me where the plug for air intake from the room is located?

On the top of the boiler, next to the coaxial, there are 3-4 screws.

Regarding the hum when igniting, it worked fine for a year, then it slowly began to appear. I called a technician, set it up, the hum decreased, but did not disappear at all. The chimney is installed correctly. A problem has arisen: error A3 began to appear, the boiler stops working, and the error occurs only at night, everything is fine during the day. I realized that the error was related to the pump. What could it be? The appearance of error A3 has become more frequent, it’s annoying,
because the boiler is switched off. Who can help solve the problem, has anyone encountered this error? Is this still a problem with the pump or fan? It's not clear in the instructions.

You need to adjust the minimum and maximum gas pressure, clean the fan. Jumper the contacts of the water pressure sensor and observe the device; if there is no error A3, it means that the microswitch on the sensor may simply be faulty, or something is wrong with your water pressure.

MG Seoul wall-mounted boiler in operation. The problem is that when the temperature was set to 65 degrees, ignition became poor, namely when it starts to buzz, then it tries to ignite several times, but not the first time, I wait 30 seconds, the burner starts to burn, everything is fine. After it turns off everything repeats. But when the temperature is set above 65 degrees, it works properly and lights up clearly. Same thing when I turn it on
hot water, I also wait for some time until ignition occurs. Tell me, what could it be?

Poor ignition - or ignition power - depends, among other things, on the minimum gas pressure on the burner, as well as the ionization electrode itself - its cleanliness and position in the combustion chamber. Clean the burner. Clean the fan. Check the network voltage. Check the pressure on the burner and adjust. Inspect and clean the surface of the heat exchanger. Maintenance generally needs to be done.

Master Gas Seoul boiler malfunction. Error A5 (low water pressure). According to the instructions, the working pressure is 1.5-2.0 bar. Minimum type 0.5. It worked well the first season, and since there was no water supply in the house, water was pumped from the public street water supply. (as soon as the pressure drops closer to 0.5 bar, pump it up). For the second season I connected it to a well (hard water) and by the end of the season problems began. As soon as the pressure drops closer to 1.3-1.4 bar, error A5 (restarting the boiler without adding water and it continues to work for a certain time). Maybe someone can tell me, I suspect that there is something with the pressure sensor. It can be turned off and the wires shorted (who knows how it works?). Or maybe the air vent has gone sour; before it was dripping droplets, but now it’s dry. Over the entire history of use, water pressure drops somehow quickly. I checked all the pipes and connections, but found no leaks. That is, lately I have been pumping up the pressure from 1.5 to 2.0 every three days. And yet, the pressure is empty expansion tank should be 0.09 MPa, how much is it in bars.

1 bar - 1 kilogram approximately, the pressure sensor is on the tube, 2 wires, put a jumper between the wires, and ideally the sensor should be replaced or removed and washed thoroughly.

Boiler malfunction Master gas Seoul 14. Worked for 2 years 4 months with almost no complaints, the only thing was adding pressure regularly (it dropped constantly although there seemed to be no leaks), and about a week ago I switched it to DHW mode, worked for a bit and gave error A4, unplugged it , turned it on again - it worked. In the morning I turned on the hot water, again the boiler hummed loudly, the pressure gauge needle ran up and down and error A4, they said to clean it
you need heat exchangers (I’ve never done this, no matter where the instructions are, the procedure for how to do it all, and it’s not difficult to do it yourself), but when I turn it back on with the heating mode, everything works normally, why is that so?

Help me understand the operation of the Master Gas Seoul 14 boiler. The problem is that when the hot water is turned on hot water goes into the heating system and comes out of the tap cold water. And the pressure drops regularly. The system does not run, I checked it several times. I thought about a three-way valve, but I read somewhere that it wasn’t the reason, but they didn’t say anything intelligible.

1. change the three-way valve.
2. pump air into the expansion tank.

The MG Seoul 14 gas boiler is in operation and hums when ignited. When it's cold the noise is stronger, when it's warm it's less. The walls of the boiler vibrate strongly when humming; if you find a point on the wall and clamp it, the hum becomes an order of magnitude less. The fan is clean. There is a feeling that the hum directly depends on the amount of air flow. I assume that the reason is acoustic resonance. Adjusting the fan speed through the settings has only an indirect effect and does not eliminate the hum completely.

The hum may be caused by the flame pulling away from the burner. There are many micro-implosions that occur, which cause resonance at a certain frequency and produce a hum. Flame separation, in turn, occurs due to a mismatch between the gas supply (its pressure) and the air speed. I made a pressure gauge and adjusted the maximum and minimum according to the instructions. The operation of the boiler has changed. After ignition, the device gradually adds pressure to the cold one. At a certain moment a hum appears. The device immediately sharply reduces the pressure to a minimum and works on it for several minutes (there is no hum at this stage, sometimes there was before the adjustment). Then he starts adding pressure again little by little. Again, at a certain moment (the pressure is approaching 80% of the maximum according to the passport), a hum appears. Again it lowers the pressure a little, and then again slowly increases it, as if trying to approach the border where the hum occurs, but prevent its occurrence. It seems that the “brains” feel the hum and are trying to set the maximum possible pressure without causing a hum. But how do they feel? I don't see the sensor. Maybe the traction sensor. It would seem that the connection between pressure and hum is obvious. When a certain pressure is reached, a hum appears. But no, in heating and hot water mode there is almost no hum, although the pressure is almost twice as high as the pressure in heating mode, in which there is hum.

Water constantly drips from the air vent and pressure is released. There is a tap with a rubber ring. What is the normal position of this tap? It must be closed or open. And if it is open, then how to set the pressure release or the valve for replacement only? I'm not afraid to take apart small things, I knocked, tapped and patted with a screwdriver, it still flows. The pressure is normal, including in the expansion tank.

Remove the air vent, disassemble it and clean it. Somewhere there is a drift or deposits due to water do not allow the float to fit tightly.

Master Gas wall-mounted boiler in operation. The boiler works normally for heating, when I turn on the hot water, after 15-20 seconds a noise appears in the boiler (as if water is being sucked in), the flame in the boiler turns off for a few seconds. This is accompanied by a second jump in pressure upward (then returns back), the hot water, of course, also stops flowing. Then everything is fine, and after 15-20 seconds everything is the same, etc. I did it
maintenance, nothing has changed. The device has been in use for less than a year and a half, the heat exchanger was cleaned, the water was ordinary, the technician was there, he said it was hard. Now after the service there is no pressure jump or pop (at first there was one, yesterday I wanted to film this moment and still no cotton this, the pressure arrow just twitches a little and the flame goes out). The water coming out of the tap is hot for a short time, then immediately cold, then barely warm, then again a little
hot, continue in the same order. I noticed that when the flame goes out, the AA error pops up for a few seconds. That is, there is something wrong with the pump or damage to the three-way valve, following the instructions, because the filter is clean.

It looks like a DHW heat exchanger. Apparently it needs to be changed.

The Seoul 16 boiler is installed and connected, when the hot water supply is turned on, a cracking sound occurs in it, the pressure arrow jumps and error A4 is displayed. Need to replace the secondary or three-way valve heat exchanger? Hot water flows, but the boiler goes out and all error A4, that is, when the faucet is opened. water, a crash can be heard from it, an arrow jumps and the boiler goes out, and still stood for a week in winter mode, no one touched it and again there was a mistake on the floor? Temperature at
DHW was installed at 55.

This is overheating of the heat exchanger. In the secondary, scale prevents the normal transfer of heat from the heating circuit to the hot water supply, i.e. it does not heat up to 55, and the device regularly tries to complete the task and raises the temperature, which leads to overheating and the corresponding sensor is triggered, it turns off.

2015-08-05 4 177


The Korean mounted gas boiler Master Gas Seoul is a good and inexpensive alternative to German and Czech models. The equipment is fully adapted to operating conditions throughout the Russian Federation. Mounted boilers operate on natural and liquefied gas. They have a built-in programmer that makes it possible to program the operation of the boiler from one day to a week.

All about the manufacturer's mounted boilers

The wall-mounted double-circuit gas heating boiler Master Gas Seoul is distinguished by its compact size and thoughtful design. The equipment has the following technical characteristics:

Rostekhnadzor issued a permit to operate the boiler, valid for all modifications of Master Gas Seoul. As a result, equipment registration and production project documentation goes through without any problems.

What are the main features of the installation

To ensure normal operation of the boiler, certain installation requirements of the manufacturer must be met:

The first start-up of the station must be carried out in the presence of a representative of the company selling the boiler. He will check the correct installation and settings and put the boiler under warranty.

Advantages of the Master Gas Seoul brand

Korean equipment invariably pleases consumers with its quality, thoughtful functionality and cost. Just recently, Master Gas Seoul boiler models were certified by Rostechnadzor and received permission to operate.

The cost of products is specially maintained on average price segment, despite the fact that in their functionality the models are more reminiscent of “premium” class equipment.

The rules for operating the boiler are quite simple to follow. Manufacturer adapted internal organization for work in the Russian Federation.

The basic package contains everything necessary for the operation of the equipment: built-in circulation pump, expansion tank, safety group and automation. After connecting to the heating system and installing a coaxial chimney for the boiler, you can immediately start it up.

Korean boiler or European?

It should be admitted that if just a few years ago this question could only be answered in favor of the European manufacturer, now, as sales reports show, more and more buyers are choosing Korean equipment. There are several reasons for this: Although boilers from Czech and German manufacturing companies still dominate in popularity, Korean products are gradually gaining ground. Therefore, we can expect a significant increase in sales in the near future.

Master Gas Seoul boilers are practically in no way inferior in functionality and ease of operation to products from leading manufacturers, but the main attractive quality for domestic consumers is their price.

Dual circuit with forced circulation water flow gas wall-mounted boiler Master Gas Seoul is presented in series of copies with indexing 14, 16, 21. The numbers after the name indicate the maximum parameter of the heated area. Respectively 140/160/210 m2. The Korean manufacturer has a reputation as a conscientious and responsible supplier of high-quality gas heating equipment for private and industrial use.

Gas wall-mounted boiler Master Gas Seoul. Characteristics of technical parameters

1. General characteristics:

  • The fuel used is a propane-butane mixture in liquefied or continuous form.
  • Recommended operating pressure incoming gas from 1.3 to 2.9 kPa.
  • Consumption gas mixture max/min 1990/620 l/h.
  • The nominal value of thermal conductivity in the heating circuit is from 14,000 to 21,000 W.
  • Thermal conductivity in the DHW circuit is 20,900 W.


  • Efficiency at rated power 92%.
  • Efficiency at power 30% - 95%.
  • Thermal output adjustable from 1.7:1 to 2.6:1.
  • Forced exhaust of combustion products.
  • The coolant is water.
  • The circulation system for liquid is hermetically sealed and forced.
  • Ignition mode - electronic ignition.
  • Automatic support of temperature parameters.
  • Temperature readings are displayed on the LCD display.

2. Characteristics of the heating circuit of the gas wall-mounted boiler Master Gas Seoul:

  • Adjustment temperature range from 40 to 80 degrees.
  • The working pressure (pressure) of water in the system is from 100 to 300 kPa.
  • Water pressure max 0.3 MPa.


3. Parameters for the Master Gas Seoul hot water supply circuit:

  • Consumption of water mass with an increase in temperature by 25 C is 11.5 l/min.
  • Adjustable temperature range from 37 to 60 C.
  • Water pressure in the system is from 15 to 1000 kPa.
  • Min water consumption at start 2.5 l/min.
  • Min water consumption for finishing stop 1.5 l/min.


Operating modes of gas wall-mounted boilers Master Gas Seoul

Gas wall-mounted units Master Gas Seoul No. 14, 16, 21 allow you to produce different modes works: heating and DHW, only DHW, frost protection, emergency mode and timer mode.

1. The heating and hot water supply mode turns on automatically when the unit is connected to the power supply and the “power” button is pressed. The display displays the corresponding icons, described in detail in the instructions for each model. The adjustment buttons are used to set the required temperature parameter in the heating circuit. Pressing the buttons causes the coolant temperature display to flicker. Finishing the setup results in automatic maintenance turning the boiler on and off.

  • The mode is changed using a special “mode selection” button on the control panel.
  • The temperature value for the DHW circuit is set using a special button. The parameter value selected as the main one is displayed on the right side of the LCD screen. The temperature setting accuracy falls within the range: from 37 to 45 degrees, the run-up is +10C, from 45 to 600C, a run-up of up to +50C is possible.
  • Automatic supply of hot water occurs from the moment the “hot” tap is opened.
  • Closing the tap automatically puts the system into heating mode.


2. The frost protection mode is activated by pressing a special button.

  • The regime comes into force from the moment the temperature drops below + 50C.
  • The burner turns on at the inlet and operates until the water temperature rises to 400C.
  • The protection mode is used in the event of a long-term absence of a tenant from the house, as an economical mode for gas or electricity consumption.

3. Mode for turning on only the hot water supply, when the heating mode is turned off. This mode allows you to summer time use the boiler as a gas water heater. When the DHW mode is set, the boiler works to produce hot water.

  • The transition is made by pressing the “mode selection” buttons until the display disappears from the screen and the temperature indicator in the DHW circuit blinks. Use the plus/minus buttons to set the selected temperature parameter. The error of the value depends on the temperature range and ranges from 10C to 50C.


4. The timer mode provides for cyclical operation of the installation. The cycle lasts 15 minutes, then there is a pause in operating mode.

  • The duration of the pause is set by the owner independently from 1 to 6 hours.
  • During operation, the water heats up over 800C.

5. Emergency operation.

  • This mode is intended for a short period of time, for extraordinary cases: failure of the control panel, malfunctions in the heating system, when gas and water pressure drops.
  • The mode is switched to when disconnecting the faulty remote control and connecting the wires to each other.
  • The boiler starts operating in heating and DHW mode, maintaining the set temperature in the circuit.

Master Gas Seoul 14 is the latest gas boiler, equipped with a closed combustion chamber and two heat exchangers, characterized by incredibly high performance and absolute safety during operation, which is ensured by the ultra-modern multi-level security system installed in the device. Ease of installation and convenient control from the remote control significantly increase the comfort when working with this device. Features and advantages of Master Gas Seoul double-circuit wall-mounted gas boilers: Designed for apartment heating. Ultra-compact overall dimensions. Copper primary heat exchanger.

Master Gas Seoul 14 - the latest gas boiler, equipped with a closed combustion chamber and two heat exchangers, is distinguished by incredibly high performance and absolute safety during operation, which is ensured by the ultra-modern multi-level security system installed in the device. Ease of installation and convenient control from the remote control significantly increase the comfort when working with this device.

Features and advantages of Master Gas Seoul double-circuit wall-mounted gas boilers:

  • Designed for apartment heating.
  • Ultra-compact overall dimensions.
  • Copper primary heat exchanger.
  • Continuous electronic flame modulation in heating and domestic hot water modes.
  • Electronic remote control remote control with large LCD display.
  • Two separate heat exchangers for heating and domestic hot water circuits.
  • Turbocharging system.
  • High efficiency.
  • Multi-level security system.
  • Self-diagnosis system.
  • Stable operation at low pressures water and gas, voltage drops 220V ± 30%.
  • Modern ergonomic design.
  • Possibility of working on liquefied gas.
  • Convenience, reliability, safety.
  • Manufactured by Daesung Celtic Enersys Co., Ltd, South Korea.

"Master Gas Seoul" is a series of modern double-circuit heating boilers that are characterized by high performance, economical fuel consumption and a long period of uninterrupted operation. The accuracy of maintaining the user-specified temperature is ±1 degree. The boilers are wall-mounted and installed vertically. It is worth noting that the equipment has a stylish, ergonomic design that will appeal to every user. The MirCli online store offers a wide range of Master Gas Seoul boilers at an attractive price.

The double-circuit gas wall-mounted boiler Master Gas Seoul with forced circulation of water flow is presented in a series of copies with indexing 14, 16, 21. The numbers after the name indicate the maximum parameter of the heated area. Respectively 140/160/210 m2. The Korean manufacturer has a reputation as a conscientious and responsible supplier of high-quality gas heating equipment for private and industrial use.

Gas wall-mounted boiler Master Gas Seoul. Characteristics of technical parameters

1. General characteristics:

  • The fuel used is a propane-butane mixture in liquefied or continuous form.
  • Recommended operating pressure of incoming gas is from 1.3 to 2.9 kPa.
  • Gas mixture consumption max/min 1990/620 l/h.
  • The nominal value of thermal conductivity in the heating circuit is from 14,000 to 21,000 W.
  • Thermal conductivity in the DHW circuit is 20,900 W.

  • Efficiency at rated power 92%.
  • Efficiency at power 30% - 95%.
  • Thermal output adjustable from 1.7:1 to 2.6:1.
  • Forced exhaust of combustion products.
  • The coolant is water.
  • The circulation system for liquid is hermetically sealed and forced.
  • Ignition mode - electronic ignition.
  • Automatic support of temperature parameters.
  • Temperature readings are displayed on the LCD display.

2. Characteristics of the heating circuit of the gas wall-mounted boiler Master Gas Seoul:

  • Adjustable temperature range from 40 to 80 degrees.
  • The working pressure (pressure) of water in the system is from 100 to 300 kPa.
  • Water pressure max 0.3 MPa.

3. Parameters for the Master Gas Seoul hot water supply circuit:

  • Consumption of water mass with an increase in temperature by 25 C is 11.5 l/min.
  • Adjustable temperature range from 37 to 60 C.
  • Water pressure in the system is from 15 to 1000 kPa.
  • Min water consumption at start 2.5 l/min.
  • Min water consumption for finishing stop 1.5 l/min.

Operating modes of gas wall-mounted boilers Master Gas Seoul

Gas wall units Master Gas Seoul No. 14, 16, 21 allow different operating modes: heating and hot water supply, only hot water supply, frost protection, emergency mode and timer mode.

1. The heating and hot water supply mode turns on automatically when the unit is connected to the power supply and the “power” button is pressed. The display displays the corresponding icons, described in detail in the instructions for each model. The adjustment buttons are used to set the required temperature parameter in the heating circuit. Pressing the buttons causes the coolant temperature display to flicker. Completion of the setting results in automatic maintenance of the boiler switching on and off.

  • The mode is changed using a special “mode selection” button on the control panel.
  • The temperature value for the DHW circuit is set using a special button. The parameter value selected as the main one is displayed on the right side of the LCD screen. The temperature setting accuracy falls within the range: from 37 to 45 degrees, the run-up is +10C, from 45 to 600C, a run-up of up to +50C is possible.
  • Automatic supply of hot water occurs from the moment the “hot” tap is opened.
  • Closing the tap automatically puts the system into heating mode.

2. The frost protection mode is activated by pressing a special button.

  • The regime comes into force from the moment the temperature drops below + 50C.
  • The burner turns on at the inlet and operates until the water temperature rises to 400C.
  • The protection mode is used in the event of a long-term absence of a tenant from the house, as an economical mode for gas or electricity consumption.

3. Mode for turning on only the hot water supply, when the heating mode is turned off. This mode allows you to use the boiler as a gas water heater in the summer. When the DHW mode is set, the boiler works to produce hot water.

  • The transition is made by pressing the “mode selection” buttons until the display disappears from the screen and the temperature indicator in the DHW circuit blinks. Use the plus/minus buttons to set the selected temperature parameter. The error of the value depends on the temperature range and ranges from 10C to 50C.

4. The timer mode provides for cyclical operation of the installation. The cycle lasts 15 minutes, then there is a pause in operating mode.

  • The duration of the pause is set by the owner independently from 1 to 6 hours.
  • During operation, the water heats up over 800C.

5. Emergency operation.

  • This mode is intended for a short period of time, for extraordinary cases: failure of the control panel, malfunctions in the heating system, when gas and water pressure drops.
  • The mode is switched to when disconnecting the faulty remote control and connecting the wires to each other.
  • The boiler starts operating in heating and DHW mode, maintaining the set temperature in the circuit.

Methods for troubleshooting boilers Master Gas Seoul

Gas boiler Master Gas Seoul. The gas pressure in the line has disappeared. Tell me, does it restart automatically after the pressure is restored?

The unit will make several attempts to start; if there is no flame, it will display an error that can be reset manually. There is a special minimum gas pressure switch to automatically start the device when pressure appears in the gas line.

We use a Master Gas Seoul 14 boiler at our dacha. Until this evening it worked without interruption. But now he has a problem. The device often overheats. How can this accident be repaired?

Probably scale has built up, which is why the duct is clogged. You need to clean the device.

The day before yesterday there was a malfunction. The appliance turns on, but the heating does not heat up. What could it be?

It is possible that air is accumulating in the batteries or excess scale in the heat exchanger. It needs to be washed.

We plan to country house install a gas boiler Master Gas Seoul. Please tell me how many watts a standard el. power of this device?

Based on the instructions, the rated electrical power for these versions of the unit is from 80.0 to 160.0 Watts.

Why do they install filters?

By purifying water and gas, filters increase the service life of the boiler. One must be installed on the pipe supplying cold water to the unit. Due to the deterioration of utility networks, the water contains an excess amount of iron, and quite large particles may be present in it. In order not to let them inside the boiler, mechanical cleaning (preferably fine) is required. There are chemical filters that
prevent scale formation in the heat exchanger. It is also recommended to purify the water entering the device from the return pipe from your own heating system. Just like water, main gas may contain mechanical impurities. The filter for it is installed in front of the gas meter or directly in front of the device.

A Master Gas Seoul 16 double-circuit gas wall-mounted boiler was installed. The next question is, why might it knock when switching from heating to hot water supply?

In your case, the problem is with the three-way valve; it needs to be replaced.

A gas wall-mounted boiler is connected Master Gas Seoul 16. Help with advice: the pressure at the minimum level (about 1 mbar) at the moment the make-up tap is opened, the pressure does not rise, and if it does rise, it is only slightly (1.1 mbar). What is the cause of the problem? In addition, it is quite noisy. The pressure in the water supply is 4.5 atmospheres.

Regarding the first, it could be that the charging system is clogged, you need to see how the expansion tank works? As for the second, if it is noisy, you need to find out whether it is the pump or the heat exchanger that is clogged.

There is a problem with the Master Gas boiler. The error AA is displayed all the time, in rare cases A4. It turns out that it is boiling, and when it starts to boil, the heating pressure gauge begins to go off scale. The water pressure through the device is twice as bad as cold water. What could be the reason?

If it boils, then the water flow is poor, you need to look at the system or the primary heat exchanger is clogged. The fact that the pressure increases will be so, because when it boils it rises. Check the hot water heat exchanger.

We operate a gas boiler Seoul 14. Give advice. Based on the technical data sheet for the device, the minimum water flow in the system to turn on in hot water supply mode is 2.5 liters of water per minute, and in my case it turns on with a water flow of 7 liters per minute. Plus, this increases water consumption. The service workers say nothing can be done. Is it really so?

Perhaps the hot water flow indicator is jammed, if possible, then disassemble and check. It's not difficult, or it may have a manufacturing defect.

Malfunction of the gas boiler Master Gas Seoul 21. Installed six months ago, it worked flawlessly, but in winter it began to make loud noises, and if you press down the lid a little with your hand, the noise subsides. It turned off a couple of times, displaying error A6. But when turned on it worked fine. But there is noise, I can’t figure out what it could be? Regarding the noise during ignition. It worked well for 1 year, but later it started to buzz a little. After the master's visit, the noise became less. The chimney is installed normally. A problem appeared: error A3 started popping up, the device stops, the most surprising thing is that the error pops up at night, everything works fine during the day. I came to the conclusion that the error was somehow related to the pump. What exactly could it be? Error A3 began to pop up frequently, this is worrying because the boiler turns off. Who can tell me how to solve this problem, maybe someone had a similar experience? Is this a pump or fan fault?

You should adjust the maximum and minimum gas pressure, and cleaning the fan is also necessary. It is recommended to bridge the contacts of the water pressure indicator and monitor the operation of the boiler. If error A3 no longer appears, it means that the switch on the indicator is faulty, or you have problems with water pressure.

Tell me about the operation of the gas boiler Master Gas Seoul 14. The problem is as follows: when the hot water is turned on, hot water enters the heating system, and cold water comes out of the tap. The pressure is constantly dropping. The system does not leak, I checked it several times. I thought the problem was with the 3-way valve, but they said it wasn't.

The 3-way valve needs to be replaced. It is recommended to pump air into the expansion tank.

A gas wall-mounted boiler Seoul 14 kW was installed. The developers poured water into the heating system. I had never encountered this type of technology before, so I had a couple of questions. I plan to fill the system with purified water. After reading, I basically figured out exactly how this needs to be done: pump using a pump through the accompanying cold water fitting that fits the unit, open the feed tap and wait until the required pressure appears in the system. Then, turn it all off at the same time, bleed the air and start the device. During its use, the water will continue to evaporate, and the pressure will drop accordingly. In order to raise it, do I just need to open the feed tap and water from the mains will fill the system to the required pressure? If you believe technical passport
The electronic part of the unit must be connected through a power stabilizer. I would like to know your opinion on this matter, is it not dangerous? I know that there is a board inside that is afraid of voltage drops. For cold water, I plan to install a filter in front of it. Need advice on which one to choose?

Your heating system has no more than 20 liters. This will not cause problems unless you add this amount or more daily. Make sure there are no leaks anywhere.

We connected the Master Gas Seoul 16 gas boiler, a malfunction appeared and an error was displayed. It was assumed that the whole problem was due to a clogged gas valve, but after checking it turned out that they were clean. What else needs to be checked?

First of all, it is necessary to check the pressure of the incoming gas, making sure that the gas meter and pressure switch are intact.

A gas wall-mounted boiler Master Gas Seoul 21 has been installed. It has stopped starting and displays an ignition error. How can I solve it and what could go wrong?

Ignition error appears when: faulty gas valve, flame detector or board is unusable, ignition wire is broken, low gas pressure.

The wall-mounted boiler Seoul 16 is in operation. The hot water supply circuit does not work: cold water runs without heating. This is our first year using it. What could have happened?

There can be many reasons for the lack of hot water supply. The heat exchanger could be clogged inside or the meter fails, or the three-way valve gets jammed and many other reasons. For example, the control board could be damaged due to voltage surges.

Gas boiler Master Gas Seoul is connected. I noticed that it began to leak a little at night. Noticed a splash of moisture through the air valve. How to fix this problem?

Presumably, due to the unsuitability of the expansion tank, the safety valve failed. It is necessary to replace the expansion tank or the valve itself.

We connected the Master Gas Seoul wall-mounted boiler. The problem is the following: when the temperature was set to 60 degrees, it began to ignite poorly, namely, when it starts to make noise, then it makes a couple of attempts to ignite, but not right away, I wait about half a minute, the nozzle starts to burn, everything is normal. After switching off everything repeats. But, if you set the temperature to more than 60 degrees, everything works well. Same story with
When you turn on the hot water, you also have to wait a while. Who knows, tell me what the reason is?

Unstable ignition or ignition strength depends on the minimum gas pressure at the nozzle. The nozzle needs to be cleaned. Fan too. Check the mains voltage. The pressure on the burner should also be adjusted. Look and clean the surface of the heat exchanger. It is recommended to carry out technical service.

Malfunction in operation of the gas boiler Master gas. Displays error A5 (low water pressure). The manual says that normal pressure is 1.5 – 2.0 mbar. Lowest 0.5. The first year it worked properly, water was pumped through the street water supply. I pumped it up as soon as the pressure reached 0.5 mbar. In the second year they connected it to the well and at the end of the year problems began. As soon as the pressure drops to 1.3 mbar, it displays error A5. Maybe someone knows, I believe that the pressure indicator is faulty. Maybe you need to turn it off and close the wiring? Or maybe the air vent has become acidified; previously it was leaking a little, but now everything is dry. Over the entire period of operation, pressure
falls very quickly. I checked all the pipes and connections, but found no leaks. Last days the pressure is 1.5-2.0 mbar (I pump it up every few days).

1 mbar is equal to approximately 1 kilogram, the pressure sensor is on the pipe, there are 2 wires, put a plug between the wires, or it is better to replace it or wash it thoroughly.

Master Gas Seoul 14 is installed. The device works properly on the heating system, but when switching to hot water supply, after a while a hum appears (sounds like water being sucked in), the fire in the device turns off for a couple of seconds. Accompanied by a few seconds of voltage surge upward (then returns back). Hot water is running out. After which everything is fine, but approximately after
everything repeats itself for half a minute. Conducted technical service, no changes. The boiler has been in operation for just over a year. The heat exchanger was cleaned, the water is normal, the technician claims that it is a bit harsh. After maintenance, the pressure does not jump and there is no popping noise. Hot water flows from the tap, but not for long, then immediately ice-cold, and then slightly warm again, then a little hotter and in the same order. I noticed that when the fire goes out, the AA error is displayed for a few seconds. It turns out that something is wrong with the pump or the three-way valve is malfunctioning.

It looks like there is a problem with the hot water heat exchanger. Most likely needs to be replaced.

It is not possible to switch the boiler from hot water supply to heating, it switches instantly. For what reason could this be happening?

What mode is displayed on the panel? Heating or shower? If the domestic water heating mode has not jammed, then there are only a few possible options: faulty flow sensor or problem with the control unit. If reboot doesn't help.

Tell me where the tap is located heating system and how to properly block it? Because the water from the hot water supply circuit is not the same as installed on the panel (much colder). Or maybe someone had a similar situation?

The heating system taps are installed directly in front of the device: on the supply and return. The water flow is large, but the gas pressure is not high.

The air vent is leaking and pressure is being released. There is a tap installed there with a rubberized ring. What is the normal tap position? Should it be open or closed? If it must be open, how can the pressure release be adjusted or does the valve need to be replaced? The pressure in the expansion tank is normal.

It is necessary to remove the air vent, disassemble and clean it.

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

_______________________________________________________________________________

OPERATION AND REPAIR OF BOILERS

Protherm Panther Protherm Stingray Protherm Bear Protherm Cheetah Evan
Ariston Egis Teplodar Cooper Atem Zhitomir Neva Lux Arderia Nova
Termona Immergas Electrolux Conord Lemax Galan Mora Aton

_______________________________________________________________________________