Instructions for gas boilers. Gas boiler: how to turn it on, operating instructions. Video: ideal conditions for burning solid fuels

Systems are experiencing a rebirth today autonomous heating. This is due to the fact that the country recently began a boom in individual construction. Vacation home It is quite difficult to connect to central communications. If this is done, then the coziness and comfort in such a home will depend on a number of unreliable factors, including the condition of the pipes, the operation of the boiler room, etc. This can also include centralized energy transmission.

If you also decide to follow the experience of the majority and choose for heating country building gas boiler, then it is definitely recommended to read the operating instructions, from which you can also learn how a gas boiler works, how to turn on this equipment, and also how to avoid its premature breakdown. For example, in order to prevent foreign bodies from entering the system, a hard cleaning filter should be installed at the inlets of running water, gas, and the heating circuit. It is also important to ensure that the system contains a voltage stabilizer, which is located at the input of the system. This will protect the control board from voltage surges in the network.

If you are wondering how to turn on a Baxi brand floor-standing gas boiler, you need to follow a certain technology. In the first step you must open gas tap, it is usually located under the equipment itself. It is important to make sure that the system has required pressure, only then can power be supplied to the device. Then you should press the “Start” button and set the device to “Winter” or “Summer” mode.

The panel has special buttons with which you can set the desired temperature values ​​in the boiler and hot water supply circuits. This will enable main burner. If you purchased a gas boiler, you need to ask how to turn it on before unpacking the product. After you have completed all the above steps, you need to make sure that the boiler is working, this will be indicated special character burning flame on the display.

Connection nuances

After you have figured out how to turn on the heating gas boiler, you can set it to the “Summer” mode, and the device will work, producing only hot domestic water. When starting is completed, plugs may form inside the fuel supply pipe. In this case, the burner will not turn on and the boiler will be blocked. In this situation, it is necessary to repeat the steps mentioned above again. Ultimately, you must ensure that gas begins to flow into the burner. Then the "R" button is pressed and held for approximately 2 seconds.

On our website you can find instructions for using gas boilers from renowned manufacturers and those just starting to conquer the world market. All explanatory documents presented to your attention in a special section are recommended for use by experts.

To simplify the search process, manuals are combined into the “Instructions” section and grouped by product category and manufacturer:

  • Vaillant;
  • Immergas;
  • Ariston;
  • Bosch and many others.

The instruction manuals are available 24 hours a day, so you can download them for free at any time.

Why you should download the electronic user manual

The instruction manual is a document with which you can fully comprehend all the secret features, features, functionality gas boilers. How to secure the process of use, avoid operational problems, and eliminate the undesirable consequences of breakdowns? You can find answers to all these questions in the operating instructions.

How to download the manual in Russian?

  1. open the “Instructions” section;
  2. find the manufacturer's brand by name;
  3. select a model and open the instructions in Russian for it;
  4. start downloading.

Modern gas boilers are high-tech modern equipment that uses natural (methane) or liquefied (propane-butane) gas to heat the coolant (water, antifreeze) - an environmentally friendly fuel, relatively cheap and convenient. Correct operation gas boilers do not pose an increased risk. However, you should strictly follow the instructions and observe safety precautions.

Work of modern gas boiler involves minimal human participation.

General instructions for use

Before you start using a gas boiler, you must connect it to the gas network, heating pipes, cold and hot water supply (if the unit is double-circuit and is also intended for cooking hot water), electrical network, which must meet technical specifications cars. Gas connections are made only by certified gas service workers. The water is connected and the boiler is started for the first time by representatives of a specialized organization for servicing heating systems. When connecting, strictly adhere to the requirements of the warranty card and operating instructions, otherwise the warranty will be void.

A gas boiler can only be used for the purposes for which it is intended.

The manufacturer is not responsible for improper operation of the boiler, violation of operating rules and for damage associated with this. This will also void the warranty.

Installation, service and other work must be carried out in full accordance with the regulatory and technical documentation and user manual. Only original spare parts must be used.

If a malfunction is detected in the operation and/or breakdown of the unit, you must immediately turn off the gas supply at the tap and call a qualified specialist. It is strictly prohibited to carry out any work on the gas boiler yourself.

When performing any work on or near air ducts and chimneys, it is necessary to turn off the device and turn off the gas. After completing the work, before turning on the boiler, you should check the functionality of the air ducts and chimneys.

When the gas boiler is turned off for a long time

  • turn off the gas tap;
  • when the boiler automation is powered from the mains and there is an electric water pump, disconnect them from the line;
  • turn off the taps of the cold and hot water supply system, heating system;
  • if the heating system is filled with water and the ambient temperature is expected to drop below 0°C, the water must be drained from the heating system;
  • The final shutdown of the unit should be entrusted to a specialist.

When cleaning the boiler, turn it off. The device can be cleaned with damp cloth rags and a soft detergent, soapy water. Do not use aggressive cleaning agents. chemical substances, including detergents, insecticides, and other toxic substances.

The use and storage of flammable substances in the same room as a gas unit is strictly prohibited.

Safety regulations

  1. Do not disassemble or dismantle the device yourself.
  2. Handle the power cord carefully.
  3. Do not place foreign objects on the unit.
  4. Do not climb on the device.
  5. Do not use chairs, stools, tables, or other unstable objects to climb up to clean the wall-mounted boiler.
  6. Monitor the coolant level and add it to the heating system in a timely manner.
  7. Some brands of boilers prohibit the use of antifreeze as a coolant.
  8. The unit must not be used by children or inexperienced users.
  9. If you smell gas, immediately stop the unit and close the main gas valve, open the windows and doors, call representatives of the gas service and a specialized heating equipment repair service by phone from another room.
  10. If you smell smoke or burning, immediately stop the device, turn off the gas valve, turn off the power supply, open windows and doors, and call representatives of a specialized heating equipment repair service.
  11. It is strictly prohibited to make changes to the gas exhaust system and automation, including the safety valve.

The boiler operating instructions are a set of rules and requirements that are attached in printed form to each model. Despite the variety of gas heating equipment, the principles of use and safety are the same for all models.

Operating principle of the boiler

Gas heaters can vary in design and technical parameters, but the principle of creating heat in the house is the same - heating the coolant (water/antifreeze) with combustion gas (natural/liquefied). Supplying gaseous fuel to a residential area is not the easiest or safest thing, but consumers are attracted to gas, its comparative cheapness and versatility.

Blue fuel can be used not only for heating, but also for heating domestic water, using columns or dual-circuit heater models. Modern equipment is equipped with effective safety systems that prevent all possible emergency situations. Nevertheless, there are operating rules that must be followed and are a guarantee of safe operation.

Precautionary measures

Despite the manufacturers' commitment to safety gas apparatus, they can still become a source of danger. The Ministry of Emergency Situations regularly reminds owners of any gas-powered equipment about the following precautions:

  1. You need to buy gas-powered appliances from organizations that have the appropriate sales license.
  2. Installation should only be carried out by specialists from the relevant services.
  3. The kit should include an instruction manual.
  4. It is prohibited to change the design of the device in any way.
  5. A technical inspection must be carried out annually.
  6. It is prohibited to reduce ventilation openings in windows and walls.
  7. If there are sealed windows, it is necessary to organize air flow.
  8. Materials that can quickly ignite should not be stored in the boiler room.
  9. It is prohibited to increase the coolant temperature above 90°C.

Posting rules

  1. The area of ​​the room in which the heater is installed is at least 7.5 m².
  2. Ceilings - from 2.2 m.
  3. There must be a window providing access to air from the street.
  4. The door should open in the direction of movement of the person leaving the room.
  5. It is prohibited to install switches in the boiler room. If they are already installed, you will have to take them outside the premises.
  6. Need to equip supply and exhaust ventilation. For every m³ of fuel consumed - 15 m² of air.
  7. The distance from the heater to elements capable of burning is 25 cm or more. To non-combustible elements - 5 cm. From the chimney to combustible parts - 40 cm, to non-combustible parts - 15 cm.
  8. The device is mounted on a perfectly flat plane, without slopes.

Chimney requirements

  1. Chimney material - steel. It is recommended to use stainless steel.
  2. Cleaning hatches and condensate drainage are required. There should be a pocket at the bottom of the chimney where deposits accumulate.
  3. The chimney is equipped with external thermal insulation, which is protected from moisture (condensation, precipitation).
  4. The height of the chimney is from 5 m and at least 2 cm above the outlet pipe.
  5. The smoke exhaust is installed on the receiving plate of the vapor trap.
  6. The expansion tank is installed at the highest point of the system.
  7. A safety group and a thermometer are installed on the supply pipeline.
  8. It is not advisable to place the device in openings, niches and other hard-to-reach places.

How to use

IN modern models heaters, human participation is reduced to a minimum. Before the device is started, it is connected to:

  • gas pipeline - gas service workers;
  • heating pipes;
  • water supply - representatives of organizations servicing heating systems.

The first launch is also carried out by employees service departments. If the instructions are violated during connection and maintenance, the warranty will be void. The equipment must be used only for the purposes intended by the manufacturer.

During installation, maintenance and repair, original spare parts must be used. If a breakdown or incorrect operation is detected, the user must immediately turn off the gas valve and call the service or gas service. Produce renovation work independently is strictly prohibited.

When performing any work on or near an air duct or chimney, turning off the gas is mandatory. Having completed the work, they check the functionality of the chimney and air duct and only then proceed to start up the device.

How to turn off the boiler correctly

If the device will not be used for a long time, perform the following actions:

  1. Close the gas valve.
  2. If the equipment is volatile, you need to disconnect the automation and water pump from the power supply.
  3. Turn off the water supply and heating valves.
  4. If the temperature is expected to drop below zero, you will have to drain the water.
  5. Call a specialist to completely turn off the equipment.

The heater is also turned off for cleaning. Clean it with a damp cloth with mild detergent and soap. The use of aggressive substances is prohibited.

Safety system

Gas-powered appliances require serious monitoring. It is provided either by a person or an automation system. The latter is capable of providing multi-stage protection that prevents dangerous situations and improves equipment safety. The main task of the protection system is to turn off the device in time by stopping the fuel supply.

Let's look at the stages of protection using the example of the floor-standing boiler "Wolf KSO". These modern devices have multi-stage protection. One of the stages is an ionization sensor that controls the flame. If the fire goes out, a signal will be sent to the control unit, it will shut off the fuel supply and prevent an accident.

The combustion chamber has a temperature sensor that monitors the heating of the coolant and prevents the firebox from quickly burning out. “Wolves” are equipped with a KTD system - chimney draft control. It prevents the accumulation of carbon monoxide. If there is no draft, combustion products begin to accumulate in the chimney, and the thermostat heats up. When the temperature limit is reached, the thermostat contacts open and the flow of fuel stops.

Automatic protection

Modern heater models are equipped with electronic control and measuring instruments that generate signals for the control unit. Automation, receiving signals from sensors, coordinates the work of all nodes. Elements that prevent various types of malfunctions and problems are safety valves, expansion tanks, air valves, smoke detectors and other devices.

What to do if problems occur

Let's look at breakdown situations using the example of Italian boilers. Italian wall and floor heaters are an example of quality and efficiency. But even with proper use, malfunctions may arise that require prompt correction.

The following problems may appear in Baksi models:

  • the burner does not light;
  • during operation, popping noises are heard in the firebox;
  • the boiler overheated;
  • the device is very noisy;
  • The sensor has failed.

The probable causes of breakdowns are associated both with violations of operating rules and with reasons beyond the control of the user:

  • moisture has entered the device;
  • low quality coolant;
  • the pressure in the gas pipeline has decreased;
  • voltage drop in the electrical network;
  • errors were made during installation.

Violation of at least one rule or norm leads to breakdowns, incorrect operation and unnecessary costs.

Frost protection

One of important rules operation of heating systems - provision is minimal permissible temperature coolant. If the system is filled with water, then when low temperatures freezing occurs, pipes and radiators become unusable. In modern models, this problem is solved - the user is relieved of the need to monitor the coolant.

For example, boilers from a South Korean manufacturer provide reliable protection from freezing. Navien is cheaper than its European counterparts, but these boilers have all the necessary protection functions, which greatly simplifies their use.

When the coolant temperature drops below 10°C, it automatically starts circulation pump. If the coolant cools down to 6°C, the burner automatically turns on, warming the coolant to 21°C.

Ignition instructions

Heaters differ in the type of ignition, so when starting different modifications there are some nuances. Before turning on the device, you need to read the ignition instructions to ensure everything is done correctly. Let's look at ignition using the example of the Italian boiler "". Before turning it on, it is important to check the system for leaks. For this purpose, the thermostat is turned on to maximum so that the switching occurs automatically. Ariston ignition process:

  • The device is connected to the mains, and the heating regulator is set to desired value temperature;
  • When the pump is turned on, a slight noise is heard;
  • when all air pockets in the pipes are eliminated, the noise will disappear;
  • the electric ignition is triggered - the boiler turns on independently.

Self-diagnosis

The process of operating heaters is simplified if they have a self-diagnosis function. Almost all European manufacturers have equipped their products with it.

For example, German “” heaters, displaying error codes on the display, allow the user to quickly understand the cause of the problem and take measures to eliminate it. If code A7 appears on the screen, it is clear that the hot water temperature sensor is faulty.

If A8 is displayed, the connection to the BUS bus is broken. This feature makes it much easier to use gas equipment, makes it easier and more comfortable.

Dangerous situations

The greatest danger is a malfunction associated with the operation of the burners. If the flame goes out, gas may accumulate in the room, which will subsequently cause an explosion. Reasons for the fire going out:

  • gas pressure has dropped below the permissible norm;
  • no draft in the chimney;
  • the supply voltage has disappeared;
  • The pilot light went out.

IN emergency situation it is necessary to immediately shut off the fuel supply to the burners - automatically or manually. Modern versions are equipped with automation devices necessary for prompt shutdown of equipment. The operation of such devices is not only convenient, but also safe.

How to prevent gas accumulation indoors

Modern safety standards provide for the installation of gas analyzers in boiler rooms; they are necessary for signaling when gas appears in the room. A special electronic valve reacts to their signals, automatically stopping the flow of fuel to the burners.

What other safety regulations are there?

  • Do not disassemble or dismantle gas devices on one's own.
  • Handle the power cord carefully.
  • Do not place foreign objects on the device.
  • Don't stand on the boiler. Do not stand on chairs, tables or other unstable objects to clean the wall-mounted boiler.
  • Monitor the coolant and add it to the system on time.
  • Be careful - in some modifications the use of antifreeze is prohibited.
  • If you smell gas, immediately turn off the gas and open windows and doors. Leave the boiler room and call the gas service.