Gas and electric boilers Mora-Top: optimal price-quality ratio. Mora Gas boiler Assortment of heating equipment and accessories from the company Mora-Top

Wall-mounted gas boiler Mora

Gas, flow-through, heat-conducting Mora boilers operating on natural gas(or propane), are designed for heating rooms with heat losses of up to 10, 18, 23, 32 or 35 kW, and combination boilers are also designed for heating domestic water.

These boilers are wall-mounted. For some types of units, combustion products are removed to the outside through a chimney, and for some - through the wall using a fan.

Fig.2. Top part

Fig.3. Open boiler with combustion products discharged into the chimney

Fig.4. Bottom part

Installation and connection of a wall-mounted boiler Mora

Fig.1. Dimensions of gas boiler Mora 5118

A - heating water - outlet - G3/4”
B - domestic water - outlet - G1/2”
C - gas - G3/4”
D - domestic water - supply - G1/2’
E - heating water - supply - G3/4”

When installing a boiler, for its further safe and economical operation, it is necessary to have a professionally completed project for the whole heating system.

The Mora gas boiler can only be installed by an authorized service organization.

To operate the unit, only the type of gas indicated on the type plate of the product can be used.

The installed and assembled unit must not be moved to a new location.

The Mohr boiler must be installed so that the socket for its electrical connection is located in an accessible place. The phase wire must be connected to the left sleeve, the neutral wire to the right, and the ground pin to the top pin.

Failure to comply with this condition will result in the burner flame going out after ignition.

The emergency thermostat, reverse draft fuse, fan and pressure switch are energized at 230 V. If it is necessary to interfere with the operation of these elements, be sure to remove the plug from the electrical outlet.

The gas boiler is installed in accordance with the projects for the heating system and gas supply of a residential building, public utility facilities, industrial buildings, etc.

If the heating system meets all requirements for operation, safety and functionality, then the boiler can be put into operation after submitting the following documents to the appropriate gas supply organization: a project for the gas supply of the facility, a certificate of readiness of the gas supply system, certificates of suitability of smoke and ventilation ducts.

Installing a Mora gas boiler on a wall

The device is designed for mounting on a wall made of non-combustible material.

The installation of the Mora 5118 boiler can only be carried out by an authorized service organization that has permission (license) to carry out this work.

The boiler can be installed in bathrooms, washbasins and showers, but we recommend installing it above the bathtub at a distance of approximately 200 mm from the walls of the bathtub. It is not permissible to install the boiler outdoors.

To follow the rules fire safety must be observed safe distance between the device and flammable materials: 100 mm - from the front wall of the boiler, 50 mm - in other directions.

In order to have an accessible approach to the functional parts of the boiler during maintenance, repair or maintenance, we recommend observing the following dimensions: 500 mm - from the front wall, 500 mm - from above (a minimum size of 200 mm must be kept to allow removal of the casing), 300 mm - from below.

There are no special requirements for flooring or coverings.

The boiler is attached to the wall with two screws or hung on brackets with two holes located on the frame of the boiler body at a distance of 280 mm from each other.

An important consideration when placing is the height of the room.

It is necessary to pay attention to the fact that the vertical dimension from the end of the upper damper of the draft rectifier to the middle of the chimney in the wall is at least 500 mm.

Connection of boilers with combustion products exhaust pipe

Mora boilers of the “turbo” design have a closed combustion chamber, sucking in air to burn fuel from the outside. During installation there are no restrictions regarding room ventilation.

The boiler can be installed using a set of connecting elements. The tubes included in the set of these connecting elements are made of of stainless steel and they can be installed on the connection panel during installation.

The device is equipped with a fan. The design of the exhaust of combustion products and the air supply can be double (coaxial) or two-pipe (separate air supply and exhaust of combustion products).

Heating

The Mora 5118 boiler will start working when it receives a signal from the room thermostat to reduce the temperature in the heated rooms.

The pump will accelerate and the gas fittings will open the flow of gas to the main burner. Heating water flows from the pump to the heat exchanger, where it is heated and then enters the heating system.

The heating water temperature is recorded by the heating water temperature sensor. Heating of heating water continues until the boiler is turned off when the desired temperature in the heated rooms is reached.

Thus, the process is repeated as long as the boiler is connected to the electrical network. The heating water temperature is set to the maximum value.

Water heating

The process of heating domestic water takes priority over the process of heating water for the heating system.

The flow of water through the domestic water flow fuse will introduce the boiler into the process of heating domestic water when the 3-way valve changes the direction of movement of the heating water, and it passes through the secondary heat exchanger, and from there back to the pump.

From the heated heating water in the secondary heat exchanger, in accordance with the temperature set by the User, the utility water is heated.

By changing the burner power, the electronics system maintains the temperature of the domestic water at the selected level.

After the end of the selection of warm domestic water, the boiler will automatically switch to the heating process.

In the process of heating domestic water, the gas pressure supplied to the main burner changes so that the temperature of the domestic water corresponds to the set one, regardless of fluctuations in water flow under the influence of fluctuations in inlet pressure, i.e., increased water flow will cause an increase in gas pressure, and vice versa.

Work safety

Safe work Mora gas boiler provides the following elements:

Electronic control and regulation unit - An electronic unit that provides and controls the activity of individual boiler elements (pump, thermostats, 3-way controlled valve, flow sensor, etc.).

Heating and service water flow sensors will not allow the main burner to ignite if there is insufficient water flow.

Emergency thermostat - will close the gas supply to the boiler if the maximum is exceeded permissible temperature water in the heat exchanger.

Backdraft preventer - If clogged chimneys(even partial), which will contribute to the entry (leakage) of combustion products into the room, then the backdraft fuse will register an increase in the temperature of the surrounding space and cause the gas supply to the main burner to close.

The boiler can be put back into operation only after the fuse has cooled down, i.e. after approximately 10 minutes, by pressing the RESET button.

Pressure switch - If the combustion product exhaust pipes become clogged (even partially), or fuel combustion deteriorates (below the established norm) under the influence of a decrease in fan speed (voltage drop in the electrical network), or the fan does not work, then thanks to the pressure switch it will not turn on boiler so that combustion products do not accumulate in a closed combustion chamber.

The backdraft safety device or pressure switch must be functional during boiler operation and their functions must not be affected by anything (for example, a change in position).

In case of repeated disconnection of the backdraft fuse or pressure switch, you must contact authorized specialists. service organization to troubleshoot and perform an operational test.

Preparation for use

When preparing a Mora wall-mounted boiler for operation, you must do the following:

Check the water pressure in the heating system,
- open the inlets and outlets of heating water (or utility water) - (valves under the boiler),
- open the gas supply to the boiler.

When putting the boiler into operation, a specialist from a service organization must:

Check the pump mode - it should be set to stage 3.

Start the boiler.

Carry out ignition control:

Turn on the boiler using the button on the control panel,
- after 5 seconds, the burner will ignite from a series of sparks - ignition lasts 5 seconds,
- repeat ignition 5 times.

Check the functions of the ionization electrode - blow off the flame from the ionization electrode - after 3 seconds the burner should go out.

The electronic control of the boiler will automatically switch to ignition mode (another attempt to ignite the burner will follow).

If the burner does not ignite, fault code E2 will appear on the display - loss of flame. To ignite, you must press the RESET button on the control panel.

Perform burner control:

Check the main burner, the flame should only be near the outlet openings,
- check the stability of the flame along the entire length of the burner plates.

Adjust heating and starting power.

Malfunctions during the operation of Mora boilers

Error E0 - Temporary malfunction, possibly a malfunction of the control and regulation unit - Call a service technician.

Error E1 - Lack of water (no water in the heating system or insufficient water flow) - De-air the heating system, radiators. Try turning the boiler on and off several times or letting in utility water (in combination boilers).

Error E2 - Boiler shutdown (for example, loss of flame control, disconnection of the backdraft fuse) - In boilers with combustion products discharged into the chimney, check the patency of the combustion paths. Press the RESET button.

Error E3 - Heating water temperature sensor is open - Call a service technician.

Error E4 - The domestic water temperature sensor is open - Call a service technician.

Error E5 - Malfunction on the safety module (automatic ignition, exceeding the maximum water temperature) - In boilers with combustion products exhaust through the wall, check the patency of the combustion products exhaust pipes or air supply.

Monitoring the functions of the Mora boiler

When carrying out an annual inspection of the boiler, it is recommended to carry out periodic checks to ensure the functionality of its functions.

Gas part - check:

High-voltage electric ignition functions with ionization fuse.

Ignition of the main burner.

Gas pressure at the nozzles during heating of heating water and domestic water, as well as at initial, minimum and maximum power.

The burner flame goes out when the boiler is turned off by the working or room thermostat, or by manual shutdown, for example, when the service water flow is closed.

Tightness of connections.

Backdraft fuse.

Heating water heating - check:

Pressure in the heating system.

Pressure in the expansion vessel (nitrogen).

Function of a 3-way controlled valve.

Pump - setting the pressure, controlling noise and tightness.

Filter at the inlet to the boiler.

Heating water flow fuse - tightness of the “0” ring.

Tightness of connections (water).

Visual inspection of primary and secondary heat exchangers, cleaning external and internal surfaces.

Functions of the purge valve (on the pump).

Domestic water heating - check:

Functions of a fuse for the flow of domestic water.

Quantitative flow of domestic water at which the fuse trips.

Tightness of the “0” ring.

Tightness of connections.

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

_______________________________________________________________________________

On page: 15 25 50 75 100

Default Name (A -> Z) Name (Z -> A) Price (ascending) Price (descending) Rating (descending) Rating (ascending) Model (A -> Z) Model (Z -> A)

Mora

ST10996

RUR 2,389.00 ST10996 01, 08. Draft rectifier (art. ST10996). On the explosive drawing, part No. 01, 08. Suitable for: 5106.1032 Gas boiler, part No. 1. 5107.1032 Gas boiler, part No. 1. 5118.1032 Termit gas boiler, part No. 1. 5119.1032 Termit gas boiler, part No. 1. 5506.1032 Instantaneous water heater, part No. 8.. 01, 08. Traction straightener (art. ST10996) Mora

Mora

ST10995

RUR 2,389.00 ST10995 01, 08. Draft breaker (art. ST10995). On the explosion drawing, part No. 01, 08. Suitable for: 5111.1032 Gas boiler, part No. 1. 5110.1032 Gas boiler, part No. 1. 5122.1032 Termit gas boiler, part No. 1. 5123.1032 Termit gas boiler, part No. 1. 5510.1032 Instantaneous water heater, part No. 8. 55.. http://site/image/cache/data/store/st5106m_1-120x120.jpg 01, 08. Traction breaker (art. ST10995) Mora

Mora

ST54008

47.00 rub. ST54008 01, 17. O-ring 16x3 (art. ST54008). On the blast drawing, part no. 01, 17. Suitable for: EK08SB.N020 Electra Light, part no. 1. PK14SK.N052 Titan gas boiler, part No. 17.. http://site/image/cache/data/store/light_1-120x120.jpg 01, 17. Ring O 16x3 (art. ST54008) Mora

Mora

ST90142

RUR 7,102.00 ST90142 01. closed combustion chamber (art. ST90142). On the explosive drawing, part No. 01. Suitable for: 5109.1032 Gas boiler, part no. 1. 5108.1032 Gas boiler, part No. 1. 5120.1032 Termit gas boiler, part No. 1. 5121.1032 Termit gas boiler, part No. 1.. http://site/image/cache/data/store/st5106m_1-120x120.jpg 01. closed combustion chamber (art. ST90142) Mora

Mora

ST90143

RUB 6,573.00 ST90143 01. closed combustion chamber 5112,5113,5125 (art. ST90143). On the explosion drawing, part No. 01. Suitable for: 5112.1032 Gas boiler, part no. 1. 5113.1032 Gas boiler, part No. 1. 5124.1032 Termit gas boiler, part No. 1. 5125.1032 Termit gas boiler, part No. 1.. http://site/image/cache/data/store/st5108m_1-120x120.jpg 01. closed combustion chamber 5112,5113,5125 (art. ST90143) Mora

Mora

ST90023

RUB 5,565.00 ST90023 01. Combustion chamber (art. ST90023). On the explosive drawing, part No. 01. Suitable for: 5116.1032 Gas boiler, part no. 1. 5117.1032 Gas boiler, part No. 1.. http://site/image/cache/data/store/st5108s_1-120x120.jpg 01. Combustion chamber (art. ST90023) Mora

Mora

ST90353

78.00 rub. ST90353 01. Small PAN clamp (art. ST90353). On the explosive drawing, part No. 01. Suitable for: PK14SK.N052 Titan gas boiler, part no. 1. VEGA10.N012 Vega instantaneous water heater, part No. 1. VEGA13.N012 Vega instantaneous water heater, part No. 1. VEGA16.N012 Vega instantaneous water heater, part No. 1. VEGA10E.N.. http://site/image/cache/data/store/titan_1-120x120.jpg 01. Small PAN clamp (art. ST90353) Mora

Mora

ST10380

RUR 16,727.00 ST10380 02, 07. Heat exchanger (art. ST10380). On the explosion drawing, part No. 02, 07. Suitable for: 5119.1032 Termit gas boiler, part No. 2. 5506.1032 Instantaneous water heater, part No. 7.. http://site/image/cache/data/store/st5119_1-120x120.jpg 02, 07. Heat exchanger (art. ST10380) Mora

Mora

ST10994

RUB 19,103.00 ST10994 02, 07. Heat exchanger - welded part (art. ST10994). On the explosion drawing, part No. 02, 07. Suitable for: 5111.1032 Gas boiler, part No. 2. 5110.1032 Gas boiler, part No. 2. 5112.1032 Gas boiler, part No. 2. 5113.1032 Gas boiler, part No. 2. 5122.1032 Termit gas boiler, part No. 2. 5123.103.. http://site/image/cache/data/store/st5106m_1-120x120.jpg 02, 07. Heat exchanger - welded part (art. ST10994) Mora

Mora

ST10988

RUB 15,374.00 ST10988 02. Heat exchanger (art. ST10988). On the explosive drawing, part No. 02. Suitable for: 5106.1032 Gas boiler, part no. 2. 5107.1032 Gas boiler, part No. 2. 5109.1032 Gas boiler, part No. 2. 5108.1032 Gas boiler, part No. 2. 5118.1032 Termit gas boiler, part No. 2. 5120.1032 Termit gas boiler, d.. http://site/image/cache/data/store/st5106m_1-120x120.jpg 02. Heat exchanger (art. ST10988) Mora

Mora

ST90457

RUB 17,609.00 ST90457 02. Primary heat exchanger (art. ST90457). On the explosion drawing, part No. 02. Suitable for: 5114.1032 Gas boiler, part no. 2. 5115.1032 Gas boiler, part No. 2. 5116.1032 Gas boiler, part No. 2. 5117.1032 Gas boiler, part No. 2.. http://site/image/cache/data/store/st5106s_1-120x120.jpg 02. Primary heat exchanger (art. ST90457) Mora

Mora

ST90303

RUB 9,345.00 ST90303 03. Burner 12 plates 5118,5120,5121 (art. ST90303). On the explosion drawing, part No. 03. Suitable for: 5118.1032 Termit gas boiler, part no. 3. 5120.1032 Termit gas boiler, part No. 3. 5121.1032 Termit gas boiler, part No. 3.. http://site/image/cache/data/store/st5118_1-120x120.jpg 03. Burner 12 plates 5118,5120,5121 (art. ST90303) Mora

Russia, Moscow region, Krasnogorsk district, r.p. Nakhabino, st. Sovetskaya 86, office 106

Czech manufacturers supply the market with high-quality and reliable heating equipment. One of the largest and most famous companies in this segment is Mora-Top. The company produces wall, floor gas and electric boilers heating, water heaters and accessories. The company's products are exported to several countries around the world, have all the appropriate certificates, and are in good demand in the heating equipment market. These are high-quality economy class products.

Mora-Top company was founded in 2000. At that time, it was a subsidiary of Mora Moravia JSC. Three years later, the company became an independent manufacturer of heating and hot water equipment. Its products entered the domestic market, the countries of the post-Soviet space, as well as Poland, Romania, Slovakia and others.

The growing demand for Mora-Top heating equipment has become an excellent incentive for development. In 2004, the company's management began construction of a new high-tech plant in the city of Unichov. Today Mora-Top production facilities are big factory, where the latest equipment is installed and more than 100 workers are involved. The quality of manufactured equipment is carefully controlled. The company cares about the impact of production on the environment and uses everything available funds for guard environment.

Assortment of heating equipment and accessories from the company Mora-Top

In addition to heating boilers, Mora-Top produces water heaters and individual elements heating systems. So, if desired, each buyer can improve the heating of the house by installing the desired regulators, turbo nozzles, burners, and chimneys. To simplify installation, the company offers sets of connecting tubes, seals and many other accessories.

Gas wall boilers

Mora-Top equipment is characterized by high efficiency and is used in domestic and industrial heating systems. The main advantage of the heating equipment of this company is the combination of reasonable price and high quality. Models are equipped with open and closed cameras combustion. Special attention The manufacturer pays attention to the safety of operation of heat generators. Some models are equipped with turbo nozzles and expansion tanks.

Electric heating equipment

Electro Mora boilers-Top reply to everyone modern requirements to efficiency, environmental friendliness, reliability and ease of use. All models are capable of operating in 10 different modes, providing rooms with heat and hot water, are distinguished by stylish ergonomic design, easy to install. The Electra series models are especially popular among buyers.

Floor-standing heat generators with atmospheric burners

These boilers run on natural gas. They are relatively inexpensive, well-assembled, durable, and are excellent for domestic heating systems. Each model is adapted to difficult conditions operation, withstands pressure changes without problems and can operate at low gas pressure in the pipeline.

Mora-Top boilers are successfully used in post-Soviet countries, where difficulties often arise with the more “capricious” operating conditions of equipment from European manufacturers. For Russia, we can recommend the Classic models: optimal price-quality ratio, adaptation to unstable operation centralized systems gas supply.

    For three years we have been using a dual-circuit gas boiler MORA TOP METEOR 18 KK. It is designed for a room of up to 190 sq.m., so for our private house of 90 sq.m. Enough with your head. As soon as we bought it, there was a problem with some kind of thermostat and the boiler was constantly going out. I had to replace the thermostat. But after that everything improved and now the boiler is working properly. Gas consumption depends on the weather, but overall it is quite economical. In winter, of course, the largest volume of gas is 180-200 cubic meters, and in spring-autumn periods much less - about 120-140. In the spring, when the nights are still cold and the day is already warm, we generally set the boiler to 1, and this is quite enough for comfortable temperature in the house. It’s convenient that the power for heating and hot water is separately regulated. It works very quietly, sometimes it’s not even clear whether it’s working at all. For three years we have been using a double-circuit gas boiler MORA TOP METEOR 18 KK. It is designed for a room of up to 190 sq.m., so for our private house of 90 sq.m. Enough with your head. As soon as we bought it, there was a problem with some kind of thermostat and the boiler was constantly going out. I had to replace the thermostat. But after that everything improved and now the boiler is working properly. Gas consumption depends on the weather, but overall it is quite economical. In winter, of course, the largest volume of gas is 180-200 cubic meters, and in the spring-autumn periods it is much less - about 120-140. In the spring, when the nights are still cold and the day is already warm, we generally set the boiler to 1, and this is quite enough for a comfortable temperature in the house (+22-23 degrees). It’s convenient that the power for heating and hot water is separately regulated. It works very quietly, sometimes I even check to see if it’s working or not. The big plus is that during a power surge the boiler does not go out. In our country, such jumps are a frequent occurrence, especially in the summer. The price of the model is at the average level - not the cheapest, but not the most expensive either. At the same time, the quality justifies the cost.

    I have been using this boiler company for a year now, I installed a gas boiler MORA TOP VEGA 10.N012. On this moment I save a lot compared to what I had without it, in the summer I paid up to 2500 per month, in winter up to 4000. With this boiler model, the savings amounted to 30% of the amount, in some months it went up to 50%. It depends on the frequency of use of the boiler. It creates an excellent environment in the house. My house has an area of ​​up to 160 sq.m. and I will say that it is more than enough for me. In terms of size and capacity, it is quite compact, I would even say one of the most compact water heaters on the market. The speakers turn on already at a water flow of 2.5 l/min, which makes me very happy.

    Three years ago, gas workers issued an order to replace the gas water heater. We didn’t bother too much with choosing a new speaker; we went to the store and bought a Mora Top 13 with piezo ignition. The purchased speaker still works today without any problems. I think three years without emergency work, for such a unit is an excellent indicator of quality. The column works constantly - we do not turn off the wick. Sometimes, when there is a big draft, it goes out; while the column was new, the wick was lit the first time, now it’s the fifth time. When there is no one at home and the wick goes out, the automation is triggered and gas does not flow into the room. When re-igniting, in order for the thermocouple to heat up and the wick to burn steadily, the gas button must be held for 30 seconds and not 10 as written in the data sheet. I think the listed disadvantages cannot be attributed to the disadvantages of this column; they are rather “age-related sores”. Compared to the old speaker from the manufacturer Neva: old column was not regulated, was lit with matches and constantly broke down. I am completely satisfied with the new Mora Top 13 speaker, and I do not regret choosing this manufacturer.

    The year before last we installed MORA-TOP SIRIUS in our apartment. Apartment area 80 square meters and well insulated from the outside, they stand plastic windows etc. Over these 2.5 years, our fuel consumption is 4000 cubic meters of gas for heating and hot water, so I can safely call the boiler economical and efficient.
    As advised in the store, we call a technician every year for preventive cleaning of soot and dust, and so far there have been no problems with the work.
    Of the minuses, I would like to note that sometimes it is very noisy when switching on in winter, but the master reassured me that most likely it is a gust of wind blowing into the chimney pipe, just during ignition. It was also necessary to change all the pipes and radiators before installing the boiler: instead of the old Soviet ones, they replaced them with more modern bimetallic ones.
    When hot water is turned on in the bathroom, in the kitchen and the heating is on at the same time, there are no problems with heating and hot water quickly reaches the mixer.
    In general, our family is happy with the purchase: the price, quality and gas savings justified replacing the old one with the modern MORA-TOP SIRIUS.

    This year we finally finished building our dacha house. And in order to stay overnight here even in winter, we decided to install a gas boiler. I’ll say right away that we decided to immediately buy a high-quality one. On the advice of a friend, we took the Mora SA 20 E boiler. It has convenient controls, is easy to use, even my mother-in-law figured it out with ease. It heats very well. We are glad!

    8 years ago I bought a MORA TOP VEGA 16 E column with electronic ignition. For many years now I have forgotten even about problems with hot water and so on. No interruptions during the entire period of operation. High quality speaker!

    We have been looking for a 15 kW gas floor-standing boiler for quite a long time, and in terms of its characteristics and cost, the Mora SA 20 E gas floor-standing boiler suited us. It operates almost silently, heats the apartment well, and is warm even in the coldest point of the apartment. The model is gas-efficient and small in size. Externally the boiler looks good, it fits into our interior


The device and internal design that the Czech ones have gas boilers Mora Top made it possible to create a new generation of heating equipment that optimally complies with European and domestic standards.

The Mora manufacturer's line includes wall-mounted and floor-mounted units, differing in different technical characteristics, operating principle and performance.

Description and characteristics of attachments

Single-circuit and double-circuit wall-mounted Czech gas boilers Mora Top have three basic modifications:


The single-circuit and double-circuit gas wall-mounted heating boiler Mora Top has a built-in programmer, a unit with which you can set work program a few days in advance.

Review of Mora floor standing boilers

Floor-standing gas heating boilers Mora Top is presented in more than ten modifications, the main difference of which is the type of burner and combustion chamber used.

To increase performance and heat transfer, it is recommended to use antifreeze. Heat exchanger and internal organization designed taking into account the use of this liquid as a coolant.

As practice shows, the Czech water-heating energy-independent floor-mounted instantaneous gas heating boiler Mora Top is optimal solution for heating country houses. The absence of complex automation, electricity-dependent components, high productivity - all this distinguishes the equipment of this series.

Carrying out installation work

Mora gas appliances are designed in such a way that installation and maintenance of boilers are as simple and easy as possible. All volatile models have a self-diagnosis function. Information about all violations is displayed on the LCD display. The boilers are equipped with Mora equipment. As a result, automation, burner and other components ensure stable and long-term operation.

Commissioning and adjustment of the boiler is carried out as follows:

  • Volatile boilers are connected to the network. The self-diagnosis function starts automatically. The controller checks the presence of pressure in the heating system and gas pipeline. When deviations are found, a signal is issued in the form of a digital value. After troubleshooting, the boiler starts up.
  • Non-volatile units do not have self-diagnosis functions, automatic flame ignition, etc. Therefore, before starting up and putting the equipment into operation, the company representative must ensure that all installation recommendations are followed. It is mandatory to install a water treatment system and a security group; you may need to connect expansion tank and a circulation pump.


Czech Mora gas boilers generally start up without any difficulties, but there are exceptions, mainly related to transportation or installation problems.

One of the common malfunctions of a double-circuit boiler is the failure of the thermocouple. After replacement, the functionality of the equipment is fully restored.

Why you should buy a Mora boiler

Mora's boilers have something that other manufacturers often miss - an understanding of the complexities and peculiarities of working in domestic conditions. A potential buyer is also attracted by the possibility of choosing a suitable model.

Presented by a huge the lineup: from 15 to 750 kW. Can be selected completely automatic installation and a classic boiler without complex automation. Simple rules operation also ensures the popularity of Czech Mora models.